S-80-6.2W �i l' I S' 4 CONTRACTOR TO VERIFY PRIOR TO EXISTING B`V.C.P.� , / 13EC3INNING CONST NEW 4" DIA. SLOPING GRADE - /// / ORCERMAIN L� �U AV I EXISTING FORCE i :se6"ocs U EXISTING 48" / vbf(ry PROPOSED d "V.C.P. 2-04 BARS "DIA• CAST EXISTING 4" DIA. CAST I.D. MANHOLE AIN BEND IRON FORCE M CONCRETE BLOCK WALL ' 8" X 8' X 16" FILLED WITH GROUT 11-44 BARS CONT. -- CONCRETE 1H I 6" SMITH BLAIR TYPE N\ 431 COUPLING EXISTING 8" V.C.P_ DETAIL @%P TIE -IN SCALE : I"- lO". EXISTING WP ENCLOSURE— ALARM NEW RADIO POUR FOOTING - , W „ \1 EXISTING B" VC.P. UNDISTURBED �= TO EXIST. STATION TO SOIL PLUG t FILL MANHOLE CHANNEL CONST NEW CHANNEL FOR NEW 8" V" TO NEW STATION EXISTING MANHOLE TYPICAL WALL SECTION.,'- SCALE: 1 "i 2'. _ NO SCALE - - .r -KNI1� 1. Grout Mall solid. Cement per AMN C150 I part Portland cement, 2 to 3 parts • loose sand, 2 parts coarse aggregate 2. Reinforcing: f's 208000 psi. &SIN A615 Grade 40 II - 3. Masonry: Cf'c w L% Iasi. Grade "A" per ANEW 4, Concrete: f'c - 2000 psi @ 28 days. I CONTROL Cement per AM C150 UNIT Q5 PANE L E. Pour foot against natural, undisturbed I ' earth. i2 I O z° I — 1 I II ® 6. slope end walls to match existing grade. -- _ - ui u I -_�- l O I I I I T 0 A T 0 A 210 Q � y I I O I EXISTING WI W i MAIN 'I s METER I � _ U CAN r O +mil ,cam s �(EXISTW41 '60 O a 1 3P I 30AS 30A$ O O l• All new construction to be within limits of existing 10 foot easrment. I 3P ® 2P O 2. Existing station to be abandoned, hackfilled with sand and brux�tto grade. I (10 I ® All existing equipment to be delivered to City Yard at 2300 Placentia Avenue • �— - -� 30 15AF E Costa Mesa, California. 3. Existing slope to be left in original condition after placement of retaining wall. I U.G. PULL ' 4. Concrete slab to be constructed so as to provide drainage to street. SOX N N I Ivi C•aD!(A) MOAN 5. Transmitter antenna to be mounted on backside of electrical equipment cabinet. I2 X16 X6 O Z "C FOR (2) m2 �wm�mcw Mse)1. 6. See specifications for backfill requirements for fiberglass pumping station basin. 1 I ( EXISTWG) 4 "X4 "X 3' —O" POWER CABLE WIREWAY 7. Contractor shall at all times have the capability of pooping ar trennsporting wage I1 to downstream manhole. I 40 EXISTING UU.G. SERVICE ZO V. - 141 3(b AND I m I EXISTING PUMPS t%lHP I /2HP Ca) sta►s swctemaar �...� 240V. 240V. - 7- ,.,'IIN NOTES: SINGLE LINE DIAGRAM (D Construct Weil series 2611 packaged puking station per detail sheet. 3. _ $9ACl'RUML NOZS: (2) 11/2 HP SUBMERSIBLE Omstruct by -pass connection per detail an sheet 3 i 1 W t�►+cN^ a`a�i T�+« PUMPS WITH 25 FT. CABLES I1 Asa Maw M saro►+o r 1. The electrical contractor (E.C.) shall be responsible for conformity to all local codes instruct 22 L.F. of 8" V.C.P. sewer. Q Ix ��+�►E u„ccrs• r ordinances, the state of California Electrical Safety Orders, the National Electrical e'•1y�, a per detail this sheet e ; ��usMU`T� ; ;. Code and any additional jurisdictions relating to the work. 1�5'J Construct rinim X11 per detail this sheet ercv aTO In the event of a conflict or inconsistency between item indicated on the plans ardor W NsesslMRY• - specifications or with code requirements, the note, specification or code which prescribes Q Construct 3" thick concrete slab , and establishes the more complete job or the higher standard shall prevail. 20 Q pAS LENTEN PI -ACT. i. The E.C. shall furnish all permits and pay all fees. Transmitter redetailslectrical panel per detail this etnset. Ise specificitiacu far lbtaeola E' CALL NZ G. AT CT14) ., . � 4' 634-8117 PRIOR TO 0. The E.C. shall make power oenections to all motor and equipment furnished by others. \°J Construct tie-in per detail this sheet (% CONSTRUCTION• r + p S. All circuit breakers, fuses and electrical equipment shall have an interrupting rating 09 Existing underground pull box, meter, 60 atop 240 volt 30 main switch and wireway to remain. • ' not less than the maxima short circuit current to which they may be subjected. Existing 30 amp 3 pole switch, 30 amp 2 pole switch, 250 VA transformer and wiring to, • � H E`Z 6. The entire electrical installation shall be grounded as required by the serving utility existing pump to be removed. • ' .I, 3 1 G o� ��. and all applicable codes. .� New 3/4" C -3 #10 feeder tap and new pump control panel (furnished by Lump supplier) . Rnatall ' qP �• 5 "►. The entire wiring system shall be tested for short circuits and grounds and have insulation in W.P. enclosure. Provide 3/4" plywood mounting board. 1 ....... .� v rssm"ioe between o nductors and to ground of not less than those required by the N.E.C. Install 2" conduit for (2) power cables and 1 -1/2" conduit for (4) float switch cables. : The E.C. shall furnish and install all conduit, wire, boxes, switches, and service devices (Cables furnished by Lump supplier) . for complete and operational electrical ' 1 _1 q s.mri'f required carp seer system• � 0 Furnish and install 2.0 ICVA, X40 -120 volt ].j! transformer and new 30 amp 2 pole switch With 1 o•t' pos�+s r"c V`asM 9. All materials and equipment shall be new and shall bear the underwriters' label and shall 15 amp fuses. ~ be installed in the manor for wtLich they were designed and approved. 0 Furnish and install 120 volt, 10 panel with (4) 15 amp 1 pole circuit breakers (2 spare). L0. All devices installed outside or in damp locations shall be approved weatherproof. f, install and connect radio unit. Provide 3/4- 'n 11. All wire shall be copper, U.L. listed, rated for 600 volts, No. 12 mi.nimm size. / plywood aalurtirmg board. slwoEma uaatT •►►D -. IraR*tt,►A mrua•+ca�+ao aY po.►iaw�ios:. 0,14. ~uA 12. The E.C. shall install all conduits and wires with a minimum number of bends and in such Provide 1/2" conduit from control panel to radio unit for alarm cocductairs. - A rw mar as to conform to the structure, avoid abstrvctiens, preserve head ram, keep openings and passageways clear and meet all structural code requirements. Furnish and install weatherproof duplex receptacle. • t \ 1 1 To 41 _. _ -- _____ - _ __ _ . _ _- __ -- ' (® Furnish and install new tempered glass pane in existing frame m door to replace broken 1 1 , 16 T 1 111'1 acT RECD►- glass• p EP '^s ® !- ltevmes ba" e�o.+oucT sredw w.womo unuT nb Auza►ww. 1 1 %9 EXISTING AND PROPOSED PUMPING STATIONS A' SCALE : 1° ■ 10'.