Loading...
S-79-9.1-9.2i :oe�eae�e�e� PROR LE SCALE 0 PLAN CURVE DATA • O • r N e c REVISIONS NO DATE DESCRIPTION _aa q o L° r qe to • 80• _ NAT. GROUND • 2 1'/i: ! _SLOPE - - 1/4" PER Ft 2% : _T0,20 - = 3 1 15 3 "A. C. O ✓ER 6 "A.0 w /M. C. 70 PRIME COAT 29022 SF. TYPE C -6 CURB ¢'GOTT a (6 "Cf) LOGO I-F 4"P-lL. '1_A,t1,01,vS 3,160 $F. CROSS GUTTER ( /,(/CL. CURB oNG P'j 4 080 _5F 6 "PC.C. pR /IiEWAY ( 16',W1,0C) 2,734 SF. STREET A/AAIE S /GA/ Q Eq ST.2EET 416A7S (7,0001-U) 4 EA ,QED WOOD //FADER 304 L.f REwOVE EA' /ST. PAVEMENT 13,829 SF. RE.tif01/E EE /ST. 4W)W 144DS 20 LF. COA/C. BLOCK WALL 6'N /GN 195 LF 11,16TALL REFLECTOY PADDLE b0A¢DS G EA SEW6e AWWA/f/OL E 3 EA 8"KC. R 600 Lf 6 "I/. C. R ."/OUSE LATEPAL 6 65 L•F. COA/C. ENCASEiL1ENT 75 LF. SHEET 0201v MANHOLE / EA. 6 "R.C.P. W.4 r&_47 A?.4 /A/ CL. 150 26.0 LF F /0,157 1,'Y0;�PA.VT (4- 0WRLETE Wle,V.) AS PE -9 5 r DWG. 5 - 3 ER 510imrxFesf! BOXES 24 EA WATE,Q SEev /CE 24 EA. 6 "900E4L (21A1G -T1TE BY F14AIGE) -1 EA 6 " GATE VAL vF I EA. 8" FLAUGED CROO I EA, 8" GATE VALVE 5 EA. 8" A.C. WATER MAIM G.L 150 I n LF 8" GLOW -OFF PEE 4TD. DWG.A"i _ 1 EA. RIP- QAP WTNICK) ILO S.E RELOCATE E %1ST. CIIAIN LINT FENCE 330 L.F. I. ALL WORK SHALL CONFORM TO THE CITY OF COSTA MESA.5TANDARDS AND SHALL MEET THE APPROVAL OF THE CITY ENGINEER. 2. ALL STREET STATION ING REFERS TO THE CENTERLINE OF THE STREET 3 PA VING AND BASE SECTIONS LIST4,19 ZN THE QUANTITY ESTIMA TEARE FOR BIDDING PURPOSES ONLY AND ARE SUBJECT TO REVISION UPON RECEIPT OFSOIL 9 TEST. 4. CURB DATA REFERS M FACE OF CURB. .5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE W /THTII£ STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, 1973 EDITION. 6. CONTRACTOR SHALL OBTAIN A PERMIT AND REQUEST INSPECTION FROM CITYENGINEER/NG DEPARTMENT 70 BE MADE 48 HOURS INADVANCEOFPERFORMING WORK. TELEPHONE : 556 -5323. 7. THEAMOUNTOFASPHALTB /NDERTOBE MIXED WITH THE M/AIERAL AGGREGATE SHALL BE 5.67• {BY DRY WEIGHT. THE EXACTAMOUNT WILL BE DETERMINED BY THE CITY ENGINEER. B, ME CITY OF COSTA MESA WILL PAY FOR THE INITIAL 601L AND MATERIALS TEST. ANY SUBSEQUENT SOIL AND MATERIALS TESTS DEEMED NECESSARYOUE70TIIEFAILUREOFT11E INITIAL TESTS WILL BE AT THE CONTRACTORS EXPENSE. 9. WHERE DRIVEWAY DEPRESSIONS ARE CONSTRUCTED THE DRIVEWAY APPROACHES SHALL BE CONSTRUCTED TO PROPERTY LINE PER CITY OF COSTA MESA STANDARD PLANS. LOCATION,TYPEANO W /DTHARETOBE_ -- APPROVED BY THE CITY ENGINEER. l0. ALL UNDERGROUND WORK SHALL BE COMPLETE PRIOR TO ANY SURFACE WORK /N7NEPUBL/CR/GHT-OF- WAY. _ _ H. STREETLIGHTS TO BE /NSTALLEDPER CITY OF COSTA MESA STD•DWSWR701,7HERAIALLOCA770AIS SUBJECT TO CITY ENGINEERS APPROVAL 12. STREETNAME SIGNS TO BE INSTAL LED BACK OFCURB OR ON BRACKET MOUNTED STREET L/GKT POLE, PER CITY OF COSTA MESA STD. DWG.N_ e06. 13 STAMP °S "ON CURB AT ALL SEWER LATERAL LOCATIONS. i� - 44 . ANY CITY BENCH MARK, MONUMENT OR TIES DESTROYED OR DISTURBED DURING CONSTRUCTION SHALL BE REPLACED. ANY CHANGE IN LOCATION OR ELEVATIONS SHALL BE REPORTED TO THE CITY ENGINEER BYA LICENSED SURVEYOR ON 8 112 "X /I "LOOSE LEAF (ONES/DE ONLY) SHOWING LOCATION AND TIES OR LEVEL RUN. 15 PROTECTALLEXIST /NGUTILITIESINPLACE- - 16 CONTRACTOR SHALL FURNISH AND 1IVSTALL ALL SIGNS, LIGHTS, BARRICA DES, 4 OTHER TRAFF /C CONTROL OR WARNING DEVICES, INCLUDIN6 FLA644FA1, AS MAY SE REmmeED BY ` T//E EA/61NFER. ALL ITEMS MENTIONED SHALL BE /N CONFORMANCE W/TH THE CURRENT REQUIREMENTS AS SPECIFIED IN THE LATEST EDIT /ON OF THE "CONSTiQUCT10N SAFETY ORDER5 "FA/LUR?E TO DO _sow /LL BEC /TED UND6P APPLICABLE SEC, OF THE C. VC 4 CORRECTIVE COSTS TO THE CITY WILL BE 01AR6ED. EWER NOTES TRE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE COSTA MESA SAA/ITARY D 1S7,Y 1CZ 1 - 2. G "YCP / OUSE CONNECTIOA/S SH A LL BE CONS TRUCTEO FROM TH 6 SEWER M A /AI TO 7HE - - - PROPEAW,vLINE FA2EACf/LOT. - = TYPICAL SECTION THEDEYELOPEPSHALL NTRgCTORWIrlIAf3 'OTPLANINDICAT /A/4 THE $ FURNISH THE SEWEe CO - = QECi9AfMENDED LOCA7 10AIS OF TIE HOUSE CONA/ECTION FOR EACH LOT PRIOR? TO SEwEP GLEN CIRCLE MA /N CONSTRUCTION. _ ALL DRIVE APP20AfW LOCATIO1.16 TO 6E VERIFIED by TEACT 5UFEEWTEUVENT A MANHOLES SHALL BEBRICLK 0RPRECA57C0NCRETEASM4N41FACTURED81VASSOCIATED RAID CUT THE tO115VEflCTIOM OF CUED S CTS INC. DR APPROVED EQUAL. CONCRETE PRODUCTS - . SEWER MANHOLE FRAA4E6• COVER SHALL BEAL14AA48 Q4 FOIIA/DARYA -1270 0R.4AAe41WV -- -_. r _ - -_ ALL F F/ EQUA(„t - _ 6. AL .EWER MANIOLEF.PAMES �COVE.PS SHALL BELE T 6'BELOW N /SHED 4RADE. 2 3 \ 7 A L L SEWER HOUSE CONNECTIONS SHALL BE PLACED AeA0R TO SURFACING OF STREETS. 1 B. THE SEWER CONTRACTORSHALL RAISE THE MANHOLE FRAME4e C04ER TO FU/1S1{ 6124,0E AFTER STREET SURFACIN4 IS COMPLETED. CONSTRUCTION NOTES \ 9. CLAY PIPE dOIN1-5 SHALL BE MECHANICAL COMPRE5510N1101NT5, "WED6E- LOCK, -SPEED - a-- COAST. 3- A. C. OVEQ6A .8(AIIM)WIHC70PRIMECOAT�SS-I SEALCLWT SEAL MA /NL /NE "OR APPROVED EQUAL. /N NO CASE WILL dOIA/TlN4 MATER /AL US /N6 NEAT 2�-�- conlsr TYPE °c 6 "CURB45UrrER PER C. C,A1,oWG. W2 302 PORTLAND CEMENT 440RTA.P bR GROUT BE PE,QA9/TED, 3 C• ON574" P. C. C. SIDEWAL I,� PER CC. MDWO..t/_°401f403 CONS T. STD• MANF/OLEPER SA41174RSIDI5T. STR }, l0. STAMP "S•' ON CURB AT SEWER LATERAL LOCATIONS, CONS T 6' A.C. P. WATER? MA /N PE2 WATEPOLST. 5TD. 10 INSTALL FIRE HYDR,4NT PE,PWATER DIST. STO.NQ5'• �• 11. COAITRACTOR SHALL REQUEST INSPECT /ON FROA1 TIE OFF /cE OFTHE NrTARY piSTP/GT t4 _SAWCUT � REMOVE EXIST. PAVEMEwr CAJ61AIFeR 24 HOU.eS P•2/0,2 TO COMMENCEMENTOFWOR� TEL. 556 5400 -JOIN FEATHER OVER TO SATISFACT /O/ OFENG /A/EER 12. PERMITSQEQU /RED SHALL BEOBTAINED FROM THESTREETDEPA,2T1PMcWr, 77FA10DRIVE 15 1AISTALL REDWOOD HEADER? 2 "X 6 " T 11 II INSTALL (700OLU) STREET LIGHT PER C.CN.OW6.Ng 70! ` COSTA MESA, PRIOR TO STRA?T OF COA/5TB!/CT /ON. CANYON DRIVE 19, CDNST. 6 "V.C.P.SEIVEe LdiEQAL to tVOeK UOT DOME IN TAE PRESEUCE OF THE D15TEICT4 AUSFECTOE K 50D.IRT TO 2ElECTIOAI SEE SHEET NO. ,2 _ o-COOT.6 "DLL DRO OPEN eU T9 I I I FEE St'D. DIM, 543 so WATER NOTES Lk, I� + CA X10 FN. 1 CONTRACTOR TO HAVE ON JOB -SITE COPY OF 1974 STANDAR?D SPEC.ONSITE ATALL T/ME5. ¢ 23 10 s' "r 7 2. 48HOUR3 AIOTICETO BEGIVEN PRIOR TO CONSTRUCT /0N. (714) 556 -5210. �esako FH' 3. BOND TO BE POSTED AT COMPLET /ON OFPROdECTFOR 10 H '% OF TOE ACTUAL CNT OF WATER FACILME6. Q TO BE HELD ONE YEAR. 2 2 11 G �I� �' 4. ALL WORK TO CONFORM M TIE 57AN22ARD SPECS. OF THECOSTA MESA COUNTY W47.6 -R D167RICT REVISED EDI T /ON I9 74. ! x w C) @ W I 22k ! M F R 1 r 5 REQUIREp SEPE,PAT /ON BETWEEN WATEP MAINS AAID SANITATIOW SEWERS_ /O'HOP /ZOA/7R1L w 21 12 5 A NO 3 ' VE,PT /CAL . 5 E E STATE HEALTH CODE FOR SPECIAL CONDITIONS• MILT r. 'G• ALL DEP051T5 FOE PLAN CI LU AUD INSPECTION WILL 6E PAID WOE TO 51GUATUeE OF GENUAL IA,ANA6EE. f p '1. No USE UTEEAL5 FOE WATER SEZVICE ;HALL DE SET TO GRADE 8Y CONTEACT02 PRIDE To TOE INSTALLATION O }� 20 13 :9 4 h OF TOE WATEE AETEE ARID 60x. °° v µ .� I LT y y _._ 1 9 14 I� -r. N 3 • ' z t LOCATION MAP O 18 15 2 Q COSTA MESA SANITARY DISTRICT 17 16 { 1 APPROVED BY 1. , F B "A_c. 1 _ EX.SEJYEB - -- _ t ENGINEER DATE ,I CANYON SEE SHT. 2 R I R BA& COSTA MESA COUNTY. WATER DISTRICT BCOYERBENGINEERING CO. (714)556, -5210 • / //�� \ ' RCL C E -� 7 KEY 'MAP 14482 BEACH BLVD. SUITE'R' WESTMINSTER CALIF 638 -3522 APPROVED BY V SCALE 1" 260' UNDER THE UPERVISION OF: - -T DELBERT D BOYER RCE13542 DATE GENERAL MANAGER DATE CONTRACTOR REFERENCES DESIGNED BY C:P DATE CHECKED BY DATE STREET SEWER 8 WATER IMPROVEMENT PLANS r FOR -. Tf2ACT NO. 9105 SHEET OF DRAWN BY CP 5 -75 CHKKEDBY APP FIELD BOOK PAGE BENCHMARK NO. 105C.CM REFERENCE PLANS RECOMENDED BY RIGHT OF WAY ACQUIRED 38 39 ELEVATION 84.96 NOTE TO CONTRACTOR 2 DESCRIPTON A SENT CB STANDARD_ DRAWING Na 302 407 403 _404• -.. �,� �6 T.IT -� E sFi ET ,,,, - , FROM 244 W /CANYON DR. TO CANYON DR. , '' . WORK STARTED RET NW COR VICTORIA 405 503 505 507 6OH 701 80L PLAN NUMBER WORK ACCEPTED !! STATE ASSIST CITY ENGINEER RIGH? A AGENT - (COSTA MESA DATUM) APPfigygD q _.:, r 9 . ; CITY ENGI EER �u✓� ' I C TY O F COSTA MESA 7 D EPARTME NT OF ENGINEERING SERVICES INSPECTED BY _ DATE 0