Loading...
Engineer of Record Declaration - 2880 Mesa Verde Drive East - 2015-03-31Noelani, Please file this email with Rob’s Conflict of Interest form for the development at 2880 Mesa Verde Drive East. Thank you Scott Carroll, SDA General Manager | Costa Mesa Sanitary District | Website: www.cmsdca.gov <http://www.cmsdca.gov/> phone: 949.645.8400 | email: scarroll@cmsdca.gov <mailto:scarroll@cmsdca.gov> | CMSD Logo2 From: Davila, Rudy [mailto:RDavila@OCSD.COM] Sent: Tuesday, March 31, 2015 1:38 PM To: Scott Carroll Cc: Millea, Kathleen Subject: RE: Alternate District Engineer Scott I looked at the impacts the proposed 13 SFRs from Tentative Tract Map (TTM) 17824 would have on the existing CMSD sewer collection system on Mesa Verde Drive and determined the existing pipe segment can handle the additional flows. In making my determination I used OCSD wastewater generation rates for low density residential development (similar to CMSD’s rates for the same residential designation) and scaled the calculated average daily flow by 2.5 (2.5 factor used for receiving 8” pipes, otherwise 2.0 used) to determine an estimated peak flow for the analysis. Similar scaling is also performed by CMSD staff however OCSD is more conservative with peak flow determination, especially when proposed developments connect to an 8” pipe as in this case. Also, I downloaded Mesa Verde Drive sewer as-builts from the CMSD website to confirm size, material composition, and slope of the existing collection system connection point. Last, I compared the combined existing and proposed flows with the full flow rate for the same existing 8” pipe and expressed as a ratio (Q prop=exist / Q Full = 0.027). A ratio over 0.50 could be a concern to the local sewer agency but that is not the case here. The calculated Q prop=exist / Q Full ratio of 0.027 tells us the receiving pipe segment has sufficient capacity to handle flows from TTM 17824. Let me know if you have any questions or comments. Thank you. Regards, Rudy Davila, P.E. / Engineer Orange County Sanitation District / Planning Division 714.593.7348 phone rdavila@ocsd.com <mailto:rdavila@ocsd.com> / www.ocsd.com <http://www.ocsd.com/> Description: Description: http://myocsd/gm/pio/Documents/We%27re%20here%20for%20you/EmailSignArt.j pg From: Scott Carroll [mailto:scarroll@cmsdca.gov] Sent: Tuesday, March 10, 2015 12:35 PM To: Davila, Rudy; Steven Shaffer Subject: FW: Alternate District Engineer Rudy – attached is the link to the District’s Hydraulic modeling and a copy of the tract map. Thank you very much for your cooperation and assistance regarding this matter. Steve – Rudy Davila is serving as CMSD’s Alternate District Engineer when Rob is the engineer of record for a private development within CMSD’s service area. Rudy may contact you with questions regarding the hydraulic model. Scott Carroll, SDA General Manager | Costa Mesa Sanitary District | Website: www.cmsdca.gov <http://www.cmsdca.gov/> phone: 949.645.8400 | email: scarroll@cmsdca.gov <mailto:scarroll@cmsdca.gov> | CMSD Logo2 From: Rob Hamers [mailto:robh2@cox.net] Sent: Monday, March 09, 2015 2:06 PM To: Scott Carroll Cc: RBH, Inc. Subject: Alternate District Engineer