CONSTRUCTION NOTES:
1 CONSTRUCT 6" VCP SEWER LATERAL ® 2% MINIMUM SLOPE (OR APPROVED EQUAL BY DISTRICT ENGINEER)
2 CONSTRUCT 6" SEWER CLEAN OUT PER CMSD STD. S -107
3 CONSTRUCT GREASE INTERCEPTOR (PER PLUMBING PLANS)
O CONSTRUCT 8" FIRE WATER LINE
O CONSTRUCT 2" DOMESTIC WATER SERVICE LINE PER MCWD STD. DWG. NO. 2, 18 AND 19.
INSTALL RPP BACKFLOW DEVICE PER MCWD STD. DWG. NO. 23
T INSTALL 2" WATER METER PER MCWD STANDARD DWG. NO. 3
O EXISTING F.H. TO REMAIN AND PROTECT IN PLACE
O INSTALL F.D.C. ASSEMBLY PER FPPI MODEL 09- 090 -00 OR APPROVED EQUAL
O INSTALL P.I.V. ASSEMBLY PER MUELLER A -20806 OR APPROVED EQUAL
10 INSTALL D.C.D.A. PER MCWD STD. DWG. NO. 17
11 CONSTRUCT RPP BACKFLOW PREVENTER PER MCWD SID. DWG. NO. 23
12 SAWCUT AND REMOVE EX. AC PAVEMENT PER CITY OF COSTA MESA STD. DWG. NO. 813
13 CONSTRUCT AC. PAVEMENT /AB & MATCH EXISTING SECTION PER CITY OF COSTA MESA SID. DWG. NO. 813
14 REMOVE EXISTING METER & CAP EXISTING SERVICE AT MAIN PER MCWD INSPECTOR'S REQUIREMENTS
15 EXISTING DOUBLE DETECTOR CHECK TO BE REMOVED
16 EXISTING FDC TO BE REMOVED
17 EXISTING PIV TO BE REMOVED AND RELOCATED
18 REMOVE EXISTING BOLLARD
1g REMOVE EXISTING VALVE AND INSTALL BLIND FLANGE PER MCWD INSPECTOR'S REQUIREMENTS
20 CAP EXISTING SEWER LATERAL
21 SAWCUT AND REMOVE EX. CONCRETE PER CITY OF COSTA MESA SID. DWG. NO. 811 10 5 0 10 20 30
22 INSTALL 314" WATER METER PER MCWD STANDARD DWG. NO. 3
GRAPHIC SCALE
23 REMOVE EXISTING UTILITIES AND CAP EXISTING SERVICE
24 EXISTING WATER VALVE (TO REMAIN)
25 REMOVE EXISTING IRRIGATION CONTROL VALVE (SEE LANDSCAPE PLANS BY OTHERS)
26 REMOVE EXISTING PARKING LIGHT STANDARD (SEE LIGHTING PLANS BY OTHERS)
27 REMOVE EXISTING TELEPHONE CABINET (SEE DRY UTILITY PLANS BY OTHERS)
28 EXISTING POST /POLE TO BE REMOVED
29 EXISTING GAS VAULT TO BE REMOVED (SEE DRY UTILITY PLANS BY OTHERS)
30 REMOVE EXIS77NG WATER VALVE AND CAP EXISTING SERVICE
31 REMOVE EXISTING GAS METER (SEE DRY UTILITY PLANS BY OTHERS)
32 CONSTRUCT 12 "x8" HOT TAP, 8" R/W VALVE, AND 8" C900 CL.200 FIRE LINE
PER MCWD SID. DWG. NO. 6, 12, 18 AND INSPECTOR'S REQUIREMENTS
33 CUT IN 6 °x6 z6" TEE , 6" R/W VALVE, AND 6" C900 CL200 FIRE LINE PER
MCWD SID. DWG. NO. 6, 12, 18 AND INSPECTOR'S REQUIREMENTS
34 REMOVE EXIS71NG SEWER CLEANOUT
35 CONSTRUCT 6" FIRE LINE
36 INSTALL 8" R/W VALVE PER MCWD STD. DWG, NO. 14A AND /OR INSPECTOR'S REQUIREMENTS
37 CONSTRUCT 2" IRRIGATION WATER SERVICE LINE PER MCWD SID. DWG. NO. 2 AND 18.
INSTALL RPP BACKFLOW DEVICE PER MCWD SID. DWG. NO. 23
38 INSTALL 1" IRRIGATION METER PER MCWD STD. DWG. NO. 3
39 CONSTRUCT FIRE HYDRANT ASSEMBLY PER MCWD SID. DWG. NO. 4 AND 16.
40 INSTALL GAS METER (SEE DRY U7ILITY PLANS BY OTHERS)
41 CONSTRUCT 1 114" DOMESTIC WATER SERVICE LINE PER MCWD SID. DWG. NO. 2, 18 AND 19.
42 CONSTRUCT 2 112" DOMESTIC WATER SERVICE LINE PER MCWD SID. DWG. NO. 2, 18 AND 19.
43 INSTALL 314" RPP DOUBLE CHECK VALVE ASSEMBLY PER MCWD SID. DWG. 23.
44 CONSTRUCT CONCRETE SIDEWALK PER CITY OF COSTA MESA SID. DWG. 411.
N39' 48' 050E 161.00'
77
i�
rn
0
3
N
h
2
MATCHLINE I
PROPOSED
BUILDING "A"
RETAIL
FF =97.20
PE =98.62
2 9
92.15 I.E.
22 9�
92.75 I.E.
y
dw MM 1 0 a mk�11111111* =.M1111111 ip 111111
W 1 W W W 1 6 41
Mal am
- 4
14 19
T,
PROPOSED VONS
FF =98.00
PE =97.42
F 18 18
16
W � I
W
I
13
MATCHLINE W A -A
Underground Service Alert
eEFORE ti Call: TOLL FREE
Pv" c O
811"
TWO WORKING
DAYS BEFORE YOU DIG
REVISIONS DESIGNED BY.•
DATE MARK BY APPROVED RCE NO. DA 7E.-
1071900 i ESS
DRAWN BY-
DA 7E.
REVIEWED BY.•
DA 7E.
NOTE:
DESIGN BASED OFF TOPO SURVEY BY TRUXAW AND ASSOCIATES, INC DATED
8/23/10.
BENCHMARK - "ONSITE TEMPORARY BENCHMARK" - EXISTING STORM DRAIN
MANHOLE ACROSS THE DRIVE ISLE FROM CVS (SW CORNER OF BUILDING); RIM
ELEVAT70N= 94.07. TEMPORARY BENCHMARK SET PER RFI 14.
X -ING
93.12 BP 6" SWR
87.64 TP 8" SD
90 RIM
L
J ^
\�C
_J
i
E
TC 1
BENCH MARK NO. CM -47 -89 ELEV. 95.30 FEET
DESCRIPTION: ORANGE COUNTY SURVEYOR'S 3 3/4' ALUMINUM DISK
LOCATION:
DESCRIBED BY ORANGE COUNTY SURVEY 1989 IN THE SOUTHERLY QUADRANT OF THE
INTERSECTION OF 177H STREET AND SANTA ANA AVENUE IN THE CITY OF COSTA MESA, 25
FEET SOU7HEAS7ERLY OF THE CEN7ERUNE OF SANTA ANA AVENUE, 110 FEET SQUTHWES7ERLY
OF THE CEN7ERUNE OF 17TH STREET, SOUTHWESTERLY OF THE SOUTHERLY BEGINNING OF CURT
RETURN FOR 17TH STREET, SET AT THE EASTERLY CORNER OF A 15 FEET BY 5 FEET CATCH
BASIN ON SANTA ANA AVENUE IN FRONT OF C177ZENS BANK, 4.5 FEET IN BACK OF CURB.
W
y
92.54 I.E. g C
�l
W n
5
12 13
X -ING
92.17 BP 6" SWR
88.19 TP 8" SO
ILINE
°1^
�O
EASEMENT NOTES:
G G G G 4O A 4 FOOT RIGHT OF WAY FOR WATER AND INCIDENTAL PURPOSES W17HIN THE LAND DESCRIBED
7 IN DEED TO NISSWA PROPERTIES, INC., RECORDED JUNE 9, 1958 IN BOOK 4308, PAGE 443, O.R.
AS PROVIDED IN AN AGREEMENT RECORDED SEPTEMBER 7, 1937 IN BOOK 909, PAGE 168, O.R.
FGA c
31 II` - _________ � 10 THREE 6 FOOT WIDE NON - EXCLUSIVE EASEMENTS FOR UNDERGROUND ELECTRICITY, WATER AND
9 -1 GAS PIPE LINES RECORDED FEBRUARY 17, 1978, BOOK 12568, PAGE 1856, O.R.
12 AN EASEMENT TO THE PACIFIC TELEPHONE AND TELEGRAPH COMPANY, RECORDED FEBRUARY
18 7, 1979, BOOK 13027, PAGE 1524, INSTRUMENT NO. 7590 (AFFECTS PARCEL 6).
I I I I I 15 0 13 AN EASEMENT TO THE PACIFIC TELEPHONE AND TELEGRAPH COMPANY, RECORDED FEBRUARY
I ' 7, 1979, BOOK 13027, PAGE 1525, O.R. (AFFECTS PARCEL 1, 4, AND 8).
I
1 I 14 AN EASEMENT TO THE PACIFIC TELEPHONE AND TELEGRAPH COMPANY, RECORDED FEBRUARY
2 ' 7, 1979, BOOK 13027, PAGE 1526, O.R. (AFFECTS PARCEL 5).
1 16 (APPROX. LOCATION) ELECTRICAL SUPPLY SYSTEM EASEMENT TO SOUTHERN CALIFORNIA EDISON
i COMPANY, RECORDED MARCH 21, 1979, BOOK 13076, PAGE 1398, INSTRUMENT NO. 31150, O.R.
I 19 WATER LINE EASEMENT TO THE MESA CONSOLIDATED WATER DISTRICT, RECORDED OCTOBER 19,
1979, BOOK 13360, PAGE 1577, O.R.
i I I I I 22 A 14 FOOT WIDE EASEMENT TO THE SOUTHERN CALIFORNIA EDISON COMPANY, RECORDED AS
I 95.50 RIM
v 2.O% I I I I 91.33 I. E. 2 I �' INSTRUMENT NO. 83- 201622 O.R. (AFFECTS A PORTION OF PARCEL 8).
I I s
S o
1 I 9
❑ EX. 6 "WATER
J�L _ (Q•M) T I _(6w) _
4EX. 8° VCP
L ��..
- 38 " ® 0.41% Na \
14 W1 WWW WW
JV W i8 6 IW 2
�W W W Iy W
W W W
IV) W W
y i
W W W L y W W
I
1
TIE—IN
I.E. n
TIE- `J
91.28 I.E.
6" VCP
(91.22 LE) W
PER POTHOLE
10
it
:III
m
1 1 1
u
O L) `V)
O
W I. W W . W W I
W W W W W LEGEND:
r W w TEL
16 ' - PROPOSED RETAINING WALL
12 I EXISTING BLOCK WALL
y 1 PROP. TELEPHONE VAULT
16 (SEE DRY :UTILITY PLANS) EXISTING CURB & GUTTER
• W W W y PROP. TRANSFORMER EXISTING PL
(SEE DRY :UTILITY PLANS) 16 EXISTING R/W
X -ING
93.00 BOT- 6" FIRE EXISTING ROPOSED FIRE HYDRANT
88.77 TOP - 24'S.D. �������������������� �■4 IS M M ��
EXISTING IRRIGATION LINE
EXISTING DOMESTIC WATER LINE
- -- - - - - -- --
- - -_�� EXISTING FIRE WATER LINE
PROPOSED FIRE WATER LINE
EXIS77NGIPROPOSED FDC
X -ING
EXISTING/PROPOSED DDC
91.21 BOT. -8' SIR �
9021 TOP - 6 IRE
EXIS77NG/PROPOSED PIV
8 I �
SJ EXIS77NGIPROPOSED SEWER CLEANOUT
I
I
1 I�
W ,
_UZ
W1 S E
W
C &S Engineers, Inc
32605 Temecula Parkway
Suite 101
Temecula, California 9259
Phone 951-694-4824 /
Fax: 951 - 694 -4713
www.cscos.com ERIC
EXPIRES:
DATE: Tf ZO.10
NO. 65970
Na &9>o
DF. 06 -30-12
0
- -(WTR�-
- -F-
A),
EDO0
5Oo
e
rG-1
Lv�
rT,
L J
IV
T
COSTA MESA SANITARY DISTRICT
3
Il` 10'2'1 I Id
APPROVED BY DATE
CITY OF COSTA MESA SHEET 2 OF 3
ONSITE WATER & SEWER PLANS FOR: CONTRACT
VONS, # 2513 ACCOUNT
COSTA MESA, CALIFORNIA
nur un
EXIS77NGIPROPOSED WATER METER
y
F
®O &'
PROPOSED GREASE INTERCEPTOR
EXISTING /PROPOSED GAS METER
(5)
EXISTING GAS VAULT
CONTRACTOR
TO
PROVIDE BID' TO
EXISTING DOUBLE DETECTOR CHECK
REMOVE AND RE
LACE EXISL
MANHOLE PER C
4SD STANDA
DS
EXISTING TELEPHONE CABINET
EXIST. SMH
EXIS77NG PARKING LIGHT
RIM EL. (95.40)
/
INV EL (90.90)
EXISTING IRRIGA77ON CONTROL VALVE
EXIS77NG BLOW OFF
EXIS71NG WATER VALVE
I
,
I
EXIS77NG POST / POLE
16
APPROX. LOC.
BLIND FLANGE
�
PROPOSED DOUBLE DETECTOR CHECK
1 I�
W ,
_UZ
W1 S E
W
C &S Engineers, Inc
32605 Temecula Parkway
Suite 101
Temecula, California 9259
Phone 951-694-4824 /
Fax: 951 - 694 -4713
www.cscos.com ERIC
EXPIRES:
DATE: Tf ZO.10
NO. 65970
Na &9>o
DF. 06 -30-12
0
- -(WTR�-
- -F-
A),
EDO0
5Oo
e
rG-1
Lv�
rT,
L J
IV
T
COSTA MESA SANITARY DISTRICT
3
Il` 10'2'1 I Id
APPROVED BY DATE
CITY OF COSTA MESA SHEET 2 OF 3
ONSITE WATER & SEWER PLANS FOR: CONTRACT
VONS, # 2513 ACCOUNT