S-96-4.21N _
d II
II
INSTALL 12"
GATE VALVE
CUT AND REMOVE --/
EXISTING 12" ACP AND
CONNECT TO 12" CMLCSP
WITH SLEEVE TYPE COUPLING
----- _ - - - --
, :� 3�''`'
,L DELETED / NOT BUILT
10'
im2kioio
6" 8 12" WATER MAIN RELOCATION
SEE SHT. NO. 10
PLAN VIEW 1
N.T.S.
CUT AND REMOVE
EXISTING 6" ACP AND
CONNECfi TO 6" CMLCSP
INSTALL 6" WITH SLEEVE TYPE COUPLING
GATE VALVE
6" CMLCSP EXIST. 6" ACP
INSTALL
6 "4" TEE J
45• ELBOW
6" WATER MAIN RELOCATION
SEE SHT. NO. 10
PLAN VIEW 2
mmmmm� SCALE: 1/4 " =I' -0" —
EXIST. 6" ACP
CUT AND REMOVE
EXISTING 6" ACP AND
CONNECT TO 6" CMLCSP
W TH r-1 TYPE COUP NG
Ri -
CUT AND REMOVE f
EXISTING 12" ACP AND
CONNECT TO 12" CMLCSP
WITH SLEEVE TYPE COUPLING
/ EXIST. 12" ACP
— INSTALL 12"
GATE VALVE
25,18
6 CMLCSP
� Install 12x12 TEE --
- -
---� - 84" I.D. MH.
Install 12x6
Concentric Reducer
Install 6" Gate Valve
ACP
r
72" I.D. MH.
8" STUB 0
CONST. 72"
I.D. M.H. —
' INV. ELEV.
25.20
t
6
� I
J
30" V.C.P.
i o
in
rt 90" R.C.P.
n CUT AND REMOVE
EXISTING 6" ACP AND
I CONNECT TO 6" CMLCSP
WITH SLEEVE TYPE COUPLING
INSTALL 6" GATE VALVE S FA66+25,QO
A .
t_9" 6" CMLCSP PLAN
3r6 =I -o to
'(II
U CUT AND REMOVE
EXISTING 6" ACP AND
CONNECT TO 6" CMLCSP
WITH SLEEVE TYPE COUPLING
6" WATER MAIN RELOCATION
SEE SHT. NO. I I
PLAN VIEW 3
SCALE: 1/4" =!' -0"
EXIST. 8" ACP
INSTALL 456 ELBOW
II
I S U i i CUT AND REMOV'
n C� = EXISTING 8" ACP
CMLCSP- --� 6" CMLCSP CONNECT TO 8"
WITH SLEEVE T11
EXIST. 6" ACP
INSTALL COUPLING
INSTALL 6" 6" GATE
GATE VALVE VALVES
`-- INSTALL �— INSTALL 90' ELBOW INSTALL
6 "x6" TEE 450 ELBOW
INSTALL 6"
INSTALL—
GATE VALVE 8 "x6" TEE
CUT AND REMOVE so,(
I I EXISTING 6" ACP AND
U CONNECT TO 6" CMLCSP
WITH SLEEVE TYPE COUPLING
6" WATER MAIN RELOCATION
SEE . N .2
PLAN VIEW 4
SCALE: 1/4 " =I' -0"
M
in
112" BOTH WAYS
45 Q 18"
4 -07
72M MANHOLE BASE REINFORCEMENT MAIN TIES
SPECIAL REINFORCEMENT PLAN
DETAIL 6
3/8"s 1' -0" KE7
6" WATER MAIN RELOCATION NOTE:
SEE SHT, NO. 13 PVC LINER PLATE 8 STANDARD REINFORCEMENT
NOT SHOWN. SEE STANDARD MANHOLE DETAILS
PLAN VIEW 5 ON SHEET 21
SCALE: 1/4 " =1' -0" —' f
EXIST. 6" V.C.P. EXIST.
30" V.
REMOVE 8 DISPOSE OF I
EXISTING BASE.
II I II
EXIST. CONSTRUCT NEW
18" V.C.P. 72" I.D. MANHOLE
EXIST. INV. ELEV. I /
6.10±
NV. ELEV, / EXIST.
25.25 >. INV, ELEV.
+a, 10 b, 25.28 * --
. I 6••
EXIST.
+ 1 — 8_V.C.P.
m 7 co V j
EXIST.
INV. ELEV,
CONSTRUCT 23 L.F. OF 1
30" Y.C.P. AT S =0.0020 EL 27.5
o.
REMOVE INTERFERING PORTIONS / REMOVE INTERFERING
OF EXISTING 18" V.C.P. PLUG / PORTIONS OF EXIST.
ENDS WITH CONCRETE. 30" V.C.P. PLUG ENDS
WITH CONCRETE.
INV. EL. 27.60
NORTHERLY TRUCK
8" STUB I
#5!12' -
BOTH WAYS a�
4 -K7
3" CLR.
X15 118"
BOTH WAY
me-m
4' -0"
CHIP OFF R.C.P.
WALL TO CLEAR
V.C.P.
PACK MORTAR
SECTION A
3/8" =I =0"
3107 .W O AS BU /LT
No C 11114
� �{• Em.5�.91
JA \car+: i
SCRIPTION IA
REVISIONS
COUNTY SANITATION DISTRICTS OF
ORANGE COUNTY, CALIFORNIA
DISTRICTS NOS. 6s7 6 14
►: 1"i OwIIB&GO
E Act Box sm
srs /�l�aaoo
BAKER- GISLER INTERCEPTOR
CONNECTION DETAILS AT STA. 86+25 AND
WATERLINE RELOCATION DETAILS 14 -1 -IA
!0 9G DESiGNEO E DRAWN �Y IS�NEET
DATE �• "l"Sa 10(. �� Tf 23
CHECKED DATE ENGINEER R.C.E. DATE OF 51 SHEETS