S-96-3.1-3.5GENERAL NOTES 1. THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE COSTA MESA SANITARY DISTRICT 2. CONTRACTOR SHALL REQUEST INSPECTION FROM THE OFFICE OF THE DISTRICT ENGINEER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. (714] 631 -1731. 3. ANY WORK PERFORMED WITHOUT INSPECTION FROM THE DISTRICT SHALL BE CONSIDERED UNACCEPTABLE. 4. CONTRACTOR SHALL OBTAIN C.M.S.D. SEWER PERMIT PRIOR TO COMMENCEMENT OF WORK FROM THE PUBLIC SERVICES DEPARTMENT CITY OF COSTA MESA, 77 FAIR DRIVE. (714] 754 -5323. 5. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS THAT MAY BE REQUIRED FROM THE LOCAL GOVERNING AGENCY AND COMPLY WITH PERMIT REQUIREMENTS. 6. CONTRACTOR TO HAVE A COPY OF APPROVED SEWER PLAN AND C.M.S.D. STANDARD PLANS AND SPECIFICATIONS ON JOB SITE AT ALL TIMES. 7, CLAY PIPE JOINTS SHALL BE TYPE 'G" MECHANICAL COMPRESSION JOINTS FOR MAIN LINE SEWER. TYPE D" JOINTS, BAND -SEAL OR APPROVED EQUAL, ARE APPROVED FOR LATERALS AND REPAIR WORK ONLY 6, 6' LATERALS SHALL BE CONSTRUCTED FROM THE SEWER MAIN TO EVERY LOT. 9, ALL LATERALS SHALL BE CONSTRUCTED PRIOR TO SURFACING OF STREETS. 10. STAMP "S" ON CURB AT SEWER LATERAL LOCATIONS. It SEWER MAIN SHALL BE AIR OR WATER TESTED MEETING DISTRICT ENGINEERS APPROVAL. 12, PRIOR TO ASPHALT CONCRETE PAVING, MANHOLE FRAMES AND COVERS SHALL BE LEFT 6" BELOW FINISHED GRADE. AFTER STREET SURFACING IS COMPLETED, FRAMES AND COVERS SHALL BE RAISED TO GRADE PER STD, DWG. NO. S -105. 13, SEWER MANHOLE FRAME AND COVER SHALL BE ALHAMBRA FOUNDRY A -1170, OR APPROVED EQUAL, COVER TO BE STAMPED 'SEWER. 14, SEWER MAIN SHALL BE BALLED AFTER ALL MANHOLE FRAMES AND COVERS HAVE BEEN RAISED TO GRADE. 15, PVC PIPE MAY BE USED ONLY WITH PRIOR APPROVAL FROM THE DISTRICT ENGINEER. 16, CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING WARNING DEVICES, FLASHING ARROW BOARDS, LIGHTS AND FLAGMEN IN ACCORDANCE WITH "WORK AREA TRAFFIC CONTROL HANDBOOK" PUBLISHED BY BUILDING NEWS, INC., LATEST EDITION. 17, TRENCH BACKFILL MATERIAL WITHIN THE LIMITS OF THE CITY OF COSTA MESA (CCM] SHALL BE CRUSHED MISCELLANEOUS BASE OR SLURRY AS DETERMINED BY CCM AND SHALL BE INSTALLED PER CCM STD. 813. TRENCH RESURFACING SHALL BE PER CCM STD, 813. A PERMIT SHALL BE OBTAINED FROM CCM PRIOR TO COMMENCING WORK. PIPE BEDDING SHALL BE PER CMSD STD, S -112. 18, NEW STRUCTURAL SECTION BEYOND TRENCH SHALL BE 10' FULL DEPTH A. C. OVER COMPACTED NATIVE SOIL. NOTICE TO CONTRACTORS: ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL PERSONS ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY WITH THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL RELATIONS, DIVISION OF INDUSTRIAL SAFETY AND HEALTH, "CONSTRUCTION SAFETY ORDERS' THE DISTRICT ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR'S AND SUBCONTRACTOR'S COMPLIANCE WITH THESE ORDERS. CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE COSTA MESA SANITARY DISTRICT AND THE DISTRICT ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE COSTA MESA SANITARY DISTRICT, OR THE DISTRICT ENGINEER. THE EXISTENCE, APPROXIMATE LOCATION AND EXTENT OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN HEREON HAVE BEEN OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN AND ANY OTHER LINES NOT OF RECORD OR NOT SHOWN IF THE CONTRACTOR, WHILE PERFORMING THE CONTRACT, DISCOVERS UTILITY FACILITIES NOT SHOWN HEREON, HE SHALL IMMEDIATELY NOTIFY THE DISTRICT ENGINEER IN WRITING. UTILITIES: Underground Service Alert CALL: TOLL FREE 1 -800 422 -4133 TWO WORKING DAYS BEFORE YOU DIG PROJECT NO. 1112100 -139 PLANS FOR CONGRESS PUMP STATION ABANDONMENT IN THE CITY OF COSTA MESA. MACARTHUR ITEM UNIT QUANTITY I CONSTRUCTS" VCP SEWER LINE L.F. 1,297 2 CONSTRUCT 6' VCP SEWER LATERAL PER DETAIL SHEET J AND CMSD STD, S- 104 -A, B.. L.F. BLVD. 3 TIE -IN EXISTING SEWER LATERAL, EACH 14 4 CONSTRUCT SEWER MANHOLE PER CMSD STD. S -100 EACH 4 5 CONSTRUCT SEWER DROP MANHOLE PER CMSD STD, S -102. EACH SUNFLOWE 6 N AVE. 1 7 PLUG EXISTING 8" VCP SEWER. EACH 4 8 REMOVE EXISTING MANHOLE FRAME, COVER & SHAFT TO 2' BELOW FINISHED SURFACE. FILL W /SAND CEMENT SLURRY AND CONSTRUCT 10" FULL DEPTH A.C. PAVEMENT. EACH 10 A ST. 9 COAST DR LUMP SUM w mRTE CONSTRUCT 6' VCP SEWER LATERAL PER CMSD STD. S- 104 -A, B. GISLER AVE. 36 DIE O 4U AN L 12 REMOVE INTERFERING PORTIONS OF EXISTING MANHOLE AND CONSTRUCT SEWER MANHOLE PER CMSD STD. S -100 AND DETAIL SHEET 4. EACH 1 ooh � o C PAULARIN AVE. BAKER a y0 ° AVE. EL CAMINO o �C ADAMS SF 9 DR ARLINGTON DR. SWAN D MERRIM Jp• O WAY FAIR 0� � m cr L.1 v WILS 9 51• 9�F •d1� � Q VIC I ST. �'� ��• sr AMI TON AVE HAMILTON ST. P'C 7 �QO 'is P, N. T. S. W. 19th. ST. W. 8th5 z ST. W z 2 T W. 16th J S a OP S ,jt,� �� �T !• s y sr� sT\P J� s AREA OF CONSTRUCTION NO DESCRIPTION PLAN SI,94 IL BY A2'7 : CITY FNG /NEf.2 0 1619S CO2PECTED ZOCAT /ON MAP_ CiYEET> LOCH TION MAP CONSTRUCTION NOTES & ES TIMA TE OF QUANTITIES: NO. ITEM UNIT QUANTITY I CONSTRUCTS" VCP SEWER LINE L.F. 1,297 2 CONSTRUCT 6' VCP SEWER LATERAL PER DETAIL SHEET J AND CMSD STD, S- 104 -A, B.. L.F. 72 3 TIE -IN EXISTING SEWER LATERAL, EACH 14 4 CONSTRUCT SEWER MANHOLE PER CMSD STD. S -100 EACH 4 5 CONSTRUCT SEWER DROP MANHOLE PER CMSD STD, S -102. EACH 1 6 RECONSTRUCT EXISTING MANHOLE BASE PER DETAILS SHEETS 2 & 4. EACH 1 7 PLUG EXISTING 8" VCP SEWER. EACH 4 8 REMOVE EXISTING MANHOLE FRAME, COVER & SHAFT TO 2' BELOW FINISHED SURFACE. FILL W /SAND CEMENT SLURRY AND CONSTRUCT 10" FULL DEPTH A.C. PAVEMENT. EACH 2 9 ABANDON EXISTING PUMP STATION AND ELECTRICAL VAULT PER DETAILS SHEET 5.z-0(:1/ANNEL )WHOLE LUMP SUM CONSTRUCT 6' VCP SEWER LATERAL PER CMSD STD. S- 104 -A, B. C.F. 36 REMOVE AND RECONSTRUCT CROSS GUTTER PER CCM STD. 415. S.F. 272 L 12 REMOVE INTERFERING PORTIONS OF EXISTING MANHOLE AND CONSTRUCT SEWER MANHOLE PER CMSD STD. S -100 AND DETAIL SHEET 4. EACH 1 TRAFFIC CONTROL NOTES CONTRACTOR TO FURNISH & SUBMIT TRAFFIC CONTROL PLAN TO THE CITY OF COSTA MESA ENGINEERING DIVISION FOR APPROVAL PRIOR TO OBTAINING PERMIT O.C.S. BENCHMARK: CM -54 -92 LOCATED IN THE SW CORNER OF VICTORIA AND PLACENTIA. 50' S/0 CL VICTORIA AND 110' W/0 CL PLACENTIA SET IN THE NE CORNER OF 4x6' CONC. CATCH BASIN 1' BEHIND CURB FACE. ELEV. 87.772 TRAFFIC - GENERAL NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH THE CALTRANS MANUAL OF TRAFFIC CONTROLS SECTION 5 FOR CONSTRUCTION AND MAINTENANCE ZONES AND WITH THE WORK AREA TRAFFIC CONTROL HANDBOOK. (LATEST EDITIONS.] 2. ALL STRIPING AND MARKING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS INCLUDING STANDARD PLAN A -20, WHEN REQUIRED BY THIS PLAN, 3. A TRAFFIC DETOUR PLAN SHALL BE SUBMITTED TO & APPROVED BY THE CITY TRANSPORTATION SERVICES DIVISION 2 WEEKS PRIOR TO WORK DEFINING ALL PHASES OF VEHICULAR TRAFFIC CONTROL IN THE WORK AREA DURING CONSTRUCTION ACTIVITY AND OVERNIGHT DURING EXCAVATION. 4. ANY WORK TO BE DONE WITHIN THE CAL TRANS RIGHTS -OF -WAY MUST BE APPROVED AND COORDINATED BY CAL TRANS, 5. POST NO PARKING' SIGNS DEFINING TIME AND DATE OF RESTRICTION 24 HOURS 06 HOURS FOR A MONDAY, 48 HOURS FOR A WEEKEND/ PRIOR TO WORK. 6. NOTIFY BUSINESSES AND RESIDENTS ADJACENT TO THE WORK AREA 1 WEEK PRIOR TO THE START OF WORK. 7, WARNING SIGNS TO BE UTILIZED MUST BE IN PLACE 1 WEEK PRIOR TO THE START OF WORK. 8. FLASHING YELLOW BEACONS, TYPE B" SHALL BE USED ON ALL C18 SIGNS AND TYPE Ill BARRICADES GUARDING THE WORK AREA OVERNIGHT. THE FLASHERS SHALL NOT BE USED TO CHANNELIZE, SEPARATE OR DELINEATE THE PATH THAT TRAFFIC IS TO FOLLOW. 9. ALL SIGNS SHALL BE REFLECTORIZED AND STANDARD IN SIZE. 10. ALL DELINEATORS SHALL BE 28" MINIMUM, TUBULAR, PORTABLE, REFLECTORIZED AND MAINTAINED ERECT, IN THE INDICATED POSITION, AT ALL TIMES AND SHALL BE REPAIRED, REPLACED, OR CLEANED AS NECESSARY TO PRESERVE THEIR APPEARANCE AND CONTINUITY. It TYPE I OR ll BARRICADES MAY BE USED IN ADDITION TO DELINEATORS, AT THE DISCRETION OF THE CONTRACTOR, WHEN THEY ARE INTENDED TO PROVIDE ADDITIONAL EMPHASIS IN AREAS WHERE WORKERS ARE PRESENT 12. THE CONTRACTOR SHALL MAINTAIN ON A 24 -HOUR BASIS ALL SIGNS DELINEATORS, BARRICADES, ETC. TO TO INSURE PROPER FLOW AND SAFETY OF TRAFFIC. THE CONTRACTOR SHALL HAVE ALL SIGNS, DELINEATORS, BARRICADES, ETC. PROPERLY INSTALLED PRIOR TO BEGINNING OF WORK. THE CONTRACTOR SHALL NOT ATTEMPT TO SWITCH TRAFFIC CONTROL TO SUBSEQUENT PHASES OF WORK DURING WORKING HOURS. 13. CONSTRUCTION OPERATIONS SHALL BE CONDUCTED IN A MANNER AS TO CAUSE AS LITTLE INCONVENIENCE AS POSSIBLE TO ABUTTING PROPERTY OWNERS. 14. THE CONTRACTOR SHALL PROVIDE FOR ACCESS TO ALL ADJACENT PROPERTIES. 15. THE CONTRACTOR SHALL UTILIZE FLAG MEN DURING WORK HOURS AS DEEMED NECESSARY BY THE CITY. 16. ADDITIONAL TRAFFIC CONTROLS, SIGNS OR BARRICADING MAY BE REQUIRED IN THE FIELD, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PLACEMENT OF ANY ADDITIONAL DEVICES NECESSARY TO ASSURE SAFETY TO THE PUBLIC AT ALL TIMES DURING CONSTRUCTION. 17 WHERE LIGHTS ARE USED TO DELINEATE THE TRAVEL WAY THROUGH AND AROUND THE WORK AREA, THEY SHALL BE TYPE "C' - STEADY BURN LAMPS. 18. ALL VEHICULAR TRAVEL LANES SHALL BE OPEN FROM 7 AM TO 8:30 AM AND FROM 3:30 PM TO 6:00 PM, 19. ALL CONFLICTING STRIPES, PAVEMENT MARKING AND LEGENDS SHALL BE COMPLETELY REMOVED BY ABRASIVE BLAST CLEANING OR OTHER METHOD APPROVED BY THE ENGINEER. 20. ALL STRIPING , PAVEMENT MARKINGS & RAISED PAVEMENT MARKERS DAMAGED BY CONSTRUCTION SHALL BE REPLACED IN KIND, STRIPING SHALL BE REPLACED WITH 2 COATS OF PAINT; THE FIRST COAT APPLIED NO LATER THAN ONE DAY FOLLOWING PAVEMENT WORK, THE SECOND COAT APPLIED 7 DAYS AFTER THE FIRST COAT 21. FOR DELINEATION OF TEMPORARY VEHICLE PATHS, USE PRESSURE SENSITIVE TRAFFIC MARKING TAPE AND /OR TYPICAL STRIPING PAINT AND /OR RAISED PAVEMENT MARKERS TO SUPPLEMENT THE CHANNELIZING DEVICES. 22. ANY TRAFFIC MARKINGS INSTALLED DUE TO DETOUR REQUIREMENTS SHALL BE REMOVED BY WET SANDBLASTING IMMEDIATELY AFTER COMPLETION OF WORK. 23. THE CONTRACTOR SHALL PROVIDE SAFE PEDESTRIAN ACCESS AT ALL TIMES. 24. TEMPORARY PROTECTIVE FENCING SHALL BE PLACED AROUND ANY OPEN TRENCH WITHIN THE PUBLIC RIGHT -OF -WAY DURING NON - CONSTRUCTION HOURS OR OTHER METHODS APPROVED BY ENGINEER. 25. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MODIFYING TRAFFIC SIGNALS AS REQUIRED TO PROVIDE FOR SAFE AND EFFICIENT MOVEMENT OF TRAFFIC; INCLUDING PHASE CHANGES, COVERING OF VEHICLE HEADS, OR OTHER HARDWARE MODIFICATIONS, THE CONTRACTOR SHALL COORDINATE WITH CITY OF COSTA MESA, TRAFFIC ENGINEERING AT 7141754 -5334, PRIOR TO DOING ANY WORK AFFECTING THE SIGNAL OPERATION OR EQUIPMENT. 26. THE PROVISIONS OF THIS PLAN SHALL APPLY UNTIL ALL PHASES OF THE WORK WITHIN PUBLIC RIGHT -OF -WAY ARE COMPLETED. CITY OF COSTA MESA 9 B'HIOkq� COSTA MESA SANITARY DISTRICT CMSD PROJECT NO. 1112 10 0 -13 9 SHEET APPROVED FOR WORK WITHIN PUBLIC RIGHT- OF- WAY C0�`fl DISTRICT ENGINEER: No. N i CONGRESS PUMP STATION RCE 31720 EXP. 12/31/96 It za qr ABANDONMENT ASSISTANT ITY ENGINEER RCE 47643 DATE9� of v�o��,S RO l B. HAMERS R.C.E. 31720 DATE OF Jr EXl A. R O - S E - 6 - - - - - Zy Q - - - - W aD y U - - - -- - ¢ • y - 00 ^ SZ4 FISTB"V.C.. WR- 12'WTLO cp - - _- .i. .. - .._ - �pn - -- _ — - 4 2 72 L.F. - " V. P., ' SE ER * 2 cs o - - _ —INSTAL CST LL .49 L.F. 8' V.C.. S W R - IL - - SCALE. HORIZ. 1 " =20' VERT. 1 " =4' 0 ' 2 STA 0#00 W 165.49/ INV. C S T A T E S T R E E T 5 =0.002 h • PROP. 48" DIA. DROP MANHOLE Id STA. 2+58.72 N. B E. SCALE 1 " "20r EXIST. 8" V.C.P. SEWER 7 M % EXIST. 48" DIA. MANHOLE PROP. 8" V.C.P. SEWER 1j FAO F y - - .. _ _ - _._. _- - - -_ � �� EXIST. 8" V.C.P. SEWER \ Z�s� EXIST B' VCP. SEWER PROTECT IN PLACE \ PROTECT IN PLACE 6 __. --- - - -.- DETAIL: MANHOLE BASE @STA. 10 +08.49 S. W. SCALE 112'-1' 20 GRAPHIC SSCALE � � � EMU l IN FEET l 1C \LlA \ �5��' (� S' � �(� SMH N0. 1 STA. 0 +00 S = r— \1� o \ STA. 0+74.31 E B W 4 CONGRESS S TREE T SEE SHEET 3 OF 5 SMH NO. 2 (C/ l /3� \ STA. 10 +00.00 S.W. 11�� 5 \\ X1104 H t�Q \ �• 'g� o ■.���. ■��■. R/W ■. .. .. . ■�� uj a II W I a4�b�`�y9�glt�' 1/ 1159�(C 1 ro1p,i h�ti1�(5 W ¢ + / IN. (0 ( �,' 1 F� 11 II 1 141 �_ L � '� �l. l' 1 ^..: �., ��, V /•- Q l io ¢ oq\ 7 0 • � 11 . ro ,q, � 1 178.5 ,/6 y C I \ •i::5:5i: ��y� a r N �• Nv .' ^ii :iiii' Yyl(C G�' j b(E . , \� 1' \Q N $�. ' 6" AC WA 1 I F. •a C, EXIST 8" VCP SEWER /PROTECT /N PLACEI�l (off W _ _ _. �k - l 1. - - -. \r __,: _.._.__ —_- - - -�` —_ - -_:_ - __ -.. _ - - iN _- __ (C .__._ _ _� Q `10.81(OF� ° I / ..�- r. ■�� ■�i, '• .. . . a > 3n .aS T. ' AC WATER • •'. 10• gti U i 111 � > vi^ - _ , ,�� ' '1 , W • I m �- EX. 33" C.M.N. S.L'. w �� � �(OQ 110•`' ' /` \ \ • I I I < 311 (C CONSTRUCTION NOTES. 1v41�� EXIST MH \ \`lpbb \ STA. 1+ 9.74 E 6 W Ol INSTALL 8' V.C.P SEWER MAIN. PIPE BEDDING PER CMSD STD, S -112, ALL (65.75/ I,WV. TRENCH REPLACEMENT PER CCM STD. 813. ti (of 4O CONSTRUCT SEWER MANHOLE PER C.M.S.D, STD. S -100. \1q1`� 11114 5O CONSTRUCT DROP MANHOLE PER CMS.D. STD. S -102. • \ 11 \g c 6 RE- CHANNEL EXIST. SEWER MANHOLE BASE PER DETAIL THIS SHEET. • Boa o� @ CMSD PROJECT NO. 1112 10 0 -13 9 SHEET 1ti (j 7O CUT &PLUG EXIST. B' V,C.P. SEWER MAIN. if CONGRESS PUMP STA TION REMOVE 6 RECONSTRUCT CROSS GUTTER PER CCM STD. 415. ; ABANDONMENT 2 11nch : 20 ft OF 5 ; of O t T 17 1 -1 f F F- Sill WEI _E 0 C. -4 07 w =y +– – J—,4- II0 cc, -+t t r< Q5 ca 44 pp N: 4f ICA. Z I I "J I I I I I T `� r ad ST LL 316r.F. 8: VC..- INSTALL 21 •28 L.F. , a 4CY.SEwtR - SCALE. • --- ------ HORIZ. 10-20' —TT- --FT VERT. lm--4' SMH NO, 2 SEE SHT 2 STA, 2+58.72 SEE SHT 2 SEE SHT 2 lm U, W 6 lFC cc L) Ll INC, • Irop "r, 7 IV lflm I LLJ 12' GRAPHIC SCALE v to .o so L-m-AME-AmmosE IN FEET I I Inch 20 ft. 4 5 6 7 C 0 N G R E S IS IS T R E E T smi SMH NO. 3 cc '3- Lu 81c L Q) R/W FN 1,0.&G.l 1FC I/ '4 2 EXIST. S' VCP SEWER TO BE ABANDONED IN PLACE 8 Z' �1� �s L—�ol llyt 1) Y"�\' Al"Ill ReA, (S F IS TERRL Ama Box cn ff x1s T, C. & wv - W/v WAI 4/1 I L cc D 7; -3 0 J9 CONSTRUCTION NOTES. VARIES 9V MINI INSTALL 8' V.C.P SEWER MAIN. PIPE BEDDING PER CMSD STD. S-112. ALL 2 MIN, EN REPLACEMENT PER CCM STD. 813. 1\ 2% m/Al, INSTALL T' 6fVCP. SEWER LATERAL (SEE DETAIL THIS SHEETI PIPE BEDDING E1011A, PER CMSD. STD. S-112. ALL TRENCH REPLACEMENT PER CCM STD. 813. \\-EX. 6' V.C.P. SEWER LA T JOIN EXIST. 6' V.C.P. SEWER LATERAL EX. 6' VC.P. SEWER LAT. 6' - 118 BEND ITYR) T PLUG EXIST. WYE (TYPJ LLJ 450 CONSTRUCT SEWER MANHOLE PER O.M.S.D. STD. S-YOO• 2 rn (D CUT & PLUG EXIST. 8" V.C.P. SEWER MAIN. 6' - 118 BEND (TYP.1 REMOVE EXIST MANHOLE FRAME, COVER & SHAFT TO 2' BELOW EX, 8' VC.P. SEWER 8' x 6' WYE ITYPJ FINISHED SURFACE. FILL WISAND CEMENT SLURRY AND CONSTRUCT FULL DEPTH PAVEMENT RETURN FRAME COVER TO CORPORATION 6' YARD, 2300 PLACENTIA AVENUE, COSTA MESA. DO NOT RE-USE ON NEW SEWER MANHOLE. REMOVE AND RECONSTRUCT CROSS GUTTER PER CCM STD. 415, DETAIL: SEWER LATERAL CONNECTIONS NOT TO SCALE ul w c1l Ito SEWER TO BE -0 5; -3 SEWER LATERAL TIE-IN NOTE. NO SEWER LATERAL CONNECTIONS TO PROPOSED SEWER MAIN WILL BE ALLOWED UNTIL SEWER MAIN HAS BEEN TESTED AND THE WORK DIV THE EXISTING MANHOLE AT S TA 2#67.21 (SEE SHT 21 HAS BEEN COMPLETED. CMSD PROJECT NO. 1112100-139 CONGRESS PUMP STATION ABANDONMENT SHEET 3 OF 5 of O � iri hrl� i�ltl it ���li il4l Ili, I -1 :. ��I�1T1; -i��. II,. -1 -�i I � '.'�. �iJ lily '.II �I- 1-: v, W cn 1 Q1 v, U 14i 060 I 63 J GRAPHIC SCALE 10 0 b t0 40 I IN FEET I 1 Inch = 20 /1. �T �w M I tiLlommom l 16t C,771 t ilr ■ I1!'I 13 IT SCALE; t I HORIZ. 1 0_20' VERT. 1" =4' C O N G R E S S S T R E E T Cal ld NJ Sol SMH N0, 4 SMH NO. 5 NA TIONAL A VENUE STA. 8+98.72 4 STA. 12.18.72 4 044 � V 3 � 040 -9); -3 4 � o r �J J, r SMH NO. 6 w k h k 115\",�P1 • ry5ti1' 1\ STA. 13 +04.82 12 L 1�� 6 • \�/ EXIST. PUMP STATION a • •• v ■• ■■ ■ ■■ gal • � � � v SEE SHT 5 G. -T N co 1 11 �� qal/ �p�1 /� h 4'64 •'� allp/ 511/ �l�p� ^lt 1p� tp %� 111 - �� / /,! EXIST. C.& 41 _ l ..I ;`� — - °0 1131 p'S�( ..p• 9 p. \ p9 l 1. l 1` 10 \4 11 i a1. \4 15 \4 all 1 �1qp \ %�. e . `�� N co ♦ - 2 i' ]0 7 7 EXIST. 8" VCP SEWER TO BE ABANDONED IN PLACE EXlS7. B" VCP SEWER TO BE ABANDONED IN PLAC EXIST, 8 h o " VCP SEWER to p - 11G� , 1p'♦„ - fi 1p� / f5 / ii p1,, ' C, ' , to N a qQ °� S% 'y�� li °°�� bl k�1 5�1� 1 1 11 11 � 15 \�• p1% 1[v p N [ ap. ap. -- 1ti 1�' •'� 1• 11 15 •$ 15 ib /,� 11 11 11 qq p4 p9 11 lq �, 1 11 1• Ali 4 4 a 4' a' a' 4' 6'ti1 1•.� ti. ti 1 1 k \a' S; h N T. C.BG._– Q 1b ati' gtil ba• -M 1•, a N L ■ ■ ■ .. A9Al! s BCx 8' AC � A TEH L )NE wM - - M somommmom R1W CC N W W O �' Zp W 5110 v U F -AN( a w o w �9r J ati5 k o EXIST. ELEC. VAULT _ f1 SEE SHT. 5 LJ Jr� r DO; �� ��� _0 3 a s w y 12 PROP. 48' DIA. MANHOLE w " y 20' PROP, 8" CONSTRUCTION NOTES. V.C.P. SEWER GGS� 4'* 1 INSTALL 6" V.CP SEWER MAIN. PIPE BEDDING PER CMSD STD. i S -112. ALL TRENCH REPLACEMENT PER CCM STD. 613. 2D INSTALL 6" V.C.P. SEWER LATERAL ISEE DETAIL SHT. 3/ PIPE BEDDING PER CMSD STD. 5 -112. ALL TRENCH REPLACEMENT PER CCM STD, 813. SEWER LATERAL TIE -IN NOTE.' F� - 3O JOIN EXIST 6" V.C.P. SEWER LATERAL CONSTRUCT SEWER MANHOLE PER CM.S.D. STD. S -100. NO SEWER LATERAL CONNECTIONS TO PROPOSED SEWER MAIN WILL BE ALLOWED UNTIL SEWER MAIN HAS BEEN TESTED AND THE WORK ON THE EXIST. 8" V.C.P. SEWER a 7T CUT 8 PLUG EXIST. 8' V.C.P. SEWER MAIN. EXISTING MANHOLE AT STA 10 +08.49 S.W. (SEE SHT 21 HAS BEEN COMPLETED. EXIST. 8' V.C.P. SEWER \�� PROTECT IN PLACE O REMOVE EXIST. MANHOLE FRAME, COVER 4 SHAFT TO 2' BELOW rri NOTE.• —EXIST. 8" V.C.P. SEWER MENE TOP 12'! OF EXIST. MANHOLE T TO BE ABANDONED FINISHED SURFACE. FILL W /SAND CEMENT SLURRY AND CONSTRUCT TO BE REMOVED. REMAINING o FULL DEPTH PAVEMENT. RETURN FRAME 6 COVER TO CORPORATION PORTION TO BE BACKFILLED 1 \� YARD, 2300 PLACENTIA AVENUE, COSTA MESA. DO NOT RE -USE ON NEW SEWER MANHOLE. CMSD PROJECT NO. 1112100 -139 W /SAND CEMENT SLURRY. \11���' v2 T EXIST. STRUCTURES TO BE ABANDONED PER DETAILS SHT 5. f0 INSTALL 6" V.C.P., SEWER LATERAL PER CMSD STD. S- 104 -A, B. PIPE BEDDING CONGRESS PUMP STA TION 1 PER CMSD STD. S -112. ALL TRENCH REPLACEMENT PER CCM STD. 813. 1 1 1 — EXIST. 8' V.C.P. SEWER @) REMOVE EXIST. MANHOLE FRAME, COVER b INTERFERING PORTIONS OF SHAFT. BACKFILL ABANDONMENT r PROTECT IN PLACE REMAINING SHAFT W /SAND CEMENT SLURRY. RETURN FRAME AND COVER TO CORPORATION DETAIL: MANHOLE BASE Q STA. 13 +04.82 YARD, 2300 PLACENTIA AVENUE, COSTA MESA. DO NOT RE -USE ON NEW SEWER MANHOLE. SCALE 112'_1' CONSTRUCT SEWER MANHOLE PER C.M.SD. STD. S -100 AND DETAIL THIS SHEET. 01 z W 6 i d W J LL h+ s GRAPh I MANHOLE ON NATIONAL AVE., S/( REMOVE EXIST. MANHOLE FRAME, & SHAFT TO 2' BELOW FINISHED SURFACE. FILL WITH SAND CEMEP SLURRY AND CONSTRUCT FULL DEPTH PAVEMENT. RETURN FRAME AND COVER TO CORPORATION Yi 2300 PLACENTIA AVE., COSTA ME DO NOT RE -USE ON NEW MANHOI SEWER zr EL EC T /CAL VA UL T SEC T /ON SCALE 1'1' A' LADDERS, WIRES, CONDUITS, VENT ETC. TO BARE WALLS. ALARM, FIED BY THE DISTRICT INSPECTOR 5RATION YARD, ALL OTHER 7NTRACTOR. PERFORATE OR BREAK ENT SLURRY. CONSTRUCT 6" P.C.C. ETE AT ALL OPENINGS TO THE