S-91-4.4i
S
f�
i
L _._
PF
GF
EXIS'
OF F
6' DIA. FLANGE (O.D. =11.5 ")
1/ 1 C.L. OF PIPE
THK. PLATE 6 "x6"
DIA. SCH.40 PIPE
1
3 1/2" DIA. SCH.40 PIPE
A 1 A
..I�[TkasS,J 2N Wei 101911
TYP.
0
to T% 2c4
0 0
12"
SECTION A -A
0
n
5/8" DIA. ALL THREAD, 6' LONG
DOUBLED NUT FOR ADJUSTMENT
NOTE: PRIME & FINISH PAINT
PER CMSD STD.
0 py III 1 OWN
90' ELB. —�
FLGxFLG
6" FLGxFLG SPOOL
12" LONG
J
O
O
a
d
J
x
J
ro
FLG.
90' ELB.
MJxFLG —
W/ CONC. KICKER
I•
MJ
90' ELB.
FLGxFLG
6" FLGxFLG SPOOL
10" LONG
8 "X6" FLGxFLG
CONCENTRIC REDUCER
EXIST. 8" F.M.
DETAIL 3-"Cr
EXISTING WET WELL
OF PUMP STATION #2
ATION
.INE
ELECT
ANDLE-
T.
SEE NOTE 2 -9
1 1
1
1 1
2" ELEC. 1 1
1
1/
CONTRACTOR TO REUSE EXISTING
ELECTRICAL CONTROL CABINET AND
EXISTING ELECTRICAL PANEL AND
RADIO. POWER TO PANEL SUPPLIED
BY SOUTH COAST PLAZA.
1
ANTICIPATED LOCATION
OF INFLOW LINE
1
1
ELEC. JUNCTION BOX
NEW WATER
LEVEL WELL
ENCLOSURE FOR 2 55 -GAL
H2O2 DRUMS
SEE SHEET 2 FOR DETAILS.
00
M
EXIST. TREE –
PROTECT IN PLACE
N
-H
6
0
co
6 "x6"x6" TEE
T,
M
DETAIL 3 - "A"
EXIST. TREE –
PROTECT IN PLACE
mm
rXl T
–40 REMOVE EXISTING WALL AND CONSTRUCT NEW 8' DIA.
PRECAST VAULT SECTIONS WITH ACCESS STEPS PER 3 -33.
3 -41 REMOVE EXISTING CONCRETE
DRAINAGE GATE.
3 -44 REMOVE PUMPS AND OTHER EQUIPMENT AND RETURN TO CMSD YARD.
CUT AND PLUG EXIST. FORCE MAIN, SUCTION, CONDUIT AND
MISCELLANEOUS OPENINGS. CUT AND REMOVE PORTION OF
STEEL VAULT. FILL VAULT WITH SAND OR SLURRY SUFFICIENT
ENOUGH TO SUPPORT NEW VALVE VAULT.
3 -4 1" AIR – RELEASE VALVE (DEZURIK)
REMOVE EXISTING AND INSTALL NEW ACCESS STEPS PER 3 -33.
–48 1" RIGID CONDUIT FROM ELEC. PANEL TO CHEM. PUMP
'�-- SEE DETAIL 3 - "C"
3 -49 REPLACE EXIST. PAVING AND STRIPING EQUAL TO
EXISTING AND TO SATISFACTION OF SOUTH COAST
PLAZA.
PRECAST VAULT FLOOR
SCALE 1 " =2'
it AS BUILT it
CONSTRUCTION NOTES
3 -1 E 460V,
5.0 HPP.)1 FLYGTJCO. (FURNISHED BY DISTRICT)
6" DISCHARGE BASE & ELBOW (FURNISHED BY DISTRICT)
3 -3 I UPPER GUIDE BAR BRACKET , STAINLESS STEEL,
(FURNISHED BY DISTRICT)
3 -4 POWER CABLE WITH WATER TIGHT CONNECTIONS
(FURNISHED BY DISTRICT)
F3---5-1 CABLE HOLDER ASSEMBLY, STAINLESS STEEL
3 -6 1" P.V.C. PIPE W/3/8" AIR BUBBLER TUBE PER
ESSCO DESIGN
3 -7 INTERMEUTATE GUIDE BAR BRACKET
(STAINLESS STEEL), FLYGT (FURNISHED BY DISTRICT)
F3---8--1 ALUMINIUM ACCESS COVER (31.75" X 42.75" INSIDE OPENING,
SINGLE DOOR) WITH STAINLESS STEEL HARDWARE. FRAME TO
BE CAST INTO VAULT ( FLYGT, ML 20 OR EQUIV., RATED ® 300 PSF)
3 -9 3" O.D. A 304 STAINLESS STEEL GUIDE BARS, 2 PER PUMP
-OR 2" CONDUIT SEAL
3 -11 72" x 96" REINFORCED CONCRETE PRECAST VAULT SECTIONS
3 -12 REINFORCED CONCRETE PRECAST VAULT LID (ACCESS COVER
FRAMES TO BE PRECAST IN LID)
3-13 6" DUCTILE IRON PIPE, FLG. X FLG.
3-14 6" D.I.P. 90' ELBOW, LONG RADIUS
3 -16 6" X 6" X 6" TEE, FLG. X FLG. X FLG.
FGR S PPE)RT PIP
3-18 8" X 6" D.I.P. REDUCER, FLG. X FLG.
3 -19 6" 125 LB. SWING CHECK VALVE BRONZED TRIMMED, SPRING &
LEVER OPERATED, (CLOW) - 2 EA.
3 -20 6" 125 LB. LEVER ACTUATED PLUG VALVE (DEZURIK)
NEEDED FeR ALION19ENT-, FEe. X FE-&.
6" 1/32 BEND (li i/'*9 eR AS
3 -22 6" BRONZE QUICK COUPLING ABLE TO ATTACH TO
DISTRICT BY -PASS HOSE
3 -25 t " DIA. PIPE SUPPORT -W/GLA� .P 3" DIA. PIPE SUPPORT PER DETAIL 3-
3 -27 2 l/-e RIGID CONDUIT TO ELEC. PANEL FOR SEWER PUMP
3 -28 1" RIGID CONDUIT TO ELEC. PANEL FOR AIR BUBBLER SYSTEM
3 -29 1" CONDUIT SEAL
3-30 6" PVC VENT PIPE
3---3 'il GRATE AND FRAME WITH PLUG
00 F3--321 RECONSTRUCT CONCRETE VAULT BASE (SUPPORT BOLTS FOR
co PUMP DISCHARGE BASE TO BE ANCHORED IN BASE)
F3---3-3-1 ACCESS STEPS, 13" O.C. PS2 -PFS (COPOLYMER POLYPROPYLENE
PLASTIC) PER M.A. INDUSTRIES, INC.
3 -34 3" PVC DRAIN PIPE
3-35 3" 90' ELBOW
8" CoUptIlle,
3 -38 CONSTRUCT 4" P.C.C. OVER 2" C.M.B.
3 -39 WATER BLAST ENTIRE MANHOLE INTERIOR. INSURE WATER
TIGHTNESS OF MANHOLE. APPLY MORTAR LEVELING COURSE
BY GUNITE METHOD. APPLY POLYURETHANE COATING PER
O.C.S.D. SPECIFICATIONS AS INCLUDED IN PROJECT
I SPECIFICATIONS. (SANCON E 100 OR EQUAL)
rXl T
–40 REMOVE EXISTING WALL AND CONSTRUCT NEW 8' DIA.
PRECAST VAULT SECTIONS WITH ACCESS STEPS PER 3 -33.
3 -41 REMOVE EXISTING CONCRETE
DRAINAGE GATE.
3 -44 REMOVE PUMPS AND OTHER EQUIPMENT AND RETURN TO CMSD YARD.
CUT AND PLUG EXIST. FORCE MAIN, SUCTION, CONDUIT AND
MISCELLANEOUS OPENINGS. CUT AND REMOVE PORTION OF
STEEL VAULT. FILL VAULT WITH SAND OR SLURRY SUFFICIENT
ENOUGH TO SUPPORT NEW VALVE VAULT.
3 -4 1" AIR – RELEASE VALVE (DEZURIK)
REMOVE EXISTING AND INSTALL NEW ACCESS STEPS PER 3 -33.
–48 1" RIGID CONDUIT FROM ELEC. PANEL TO CHEM. PUMP
'�-- SEE DETAIL 3 - "C"
3 -49 REPLACE EXIST. PAVING AND STRIPING EQUAL TO
EXISTING AND TO SATISFACTION OF SOUTH COAST
PLAZA.
PRECAST VAULT FLOOR
SCALE 1 " =2'
it AS BUILT it