S-91-4.2i< s EXIST. VALVE VAULT TO REMAIN EXIST. WET WELL OF PUMP STATION # 2 EXIST. 81. 1 EXIST. 10' ESMNT. TO CMSD PER O.R. 1130/486 -487 / i EXIST. M.H. i EXIST. 8" OVERFLOW LINE TO BE REMOVED CUT & PLUG CUT & PLUG , DETAIL "A" REMOVE EXIST. CONCRETE SEE SHEET 3 FOR INSTALLATION OF NEW EQUIPMENT a N DETAIL "B" ODOR CONTROL ENCLOSURE EXIST. 6" BRONZE QUICK COUPLING TO REMAIN EXIST. 4" C.I. FO f- TO REMAIN EXIST. 8" SEWER---\\ Al MAIN _ EXIST. VALVE VAULT TO REMAIN ai a:+ A cuu v WATER LEVEL WELL EXIST. WET WELL OF PUMP STATION # 1 9XIST. 10" INFLOW 105.44 �.J inn 7c RECONSTRUCT BASE AND WALLS AS SHOWN ON SHEET 3 11 A 170 '*' FH WM VAULT r2z V\ I , O AIR VENT WM VAULT w EXISTING EDISON VAULT SCALE 1"=4' 7 EXISTING PARKING STRUCTURE EXIST. 6" BRONZE QUICK COUPLING -� I FORCE M IAN AIR O VENT �� \nNTEN. — RELOCATE CONSTRUCTION NOTES T�WALLT '7 p �l 2 -1 INSTALL 8" VCP GRAVITY SEWER LINE F-2 REMOVE PUMPS AND OTHER EQUIPMENT. FILL EXISTING VAULT J. =' WITH SLURRY AND 1' OF CONCRETE UNDER NEW CHANNEL "A ". MAKE CHANNEL AS SHOWN IN DETAIL EXIST. ESMNT. TO CMSD 0 CUT EXISTING PIPE. INSTALL BLIND FLANGE. ; 2 -4 FURNISH 2 55— GALLON HYDROGEN PEROXIDE DRUMS WITH 50% H2O2 SOLUTION. 2 -5 INSTALL SOLID—STATE ELECTRONIC CHEMICAL METERING PUMP PER PRECISION CONTROL PRODUCTS, 1100 SERIES EXISTING: EXISTING: WITH MOUNTING BRACKET. FURNISH AND INSTALL PLASTIC SOUTH COAST PLAZA SOUTH COAST PLAZA HOSE FROM DRUM TO PUMP TO WET WELL. #2 PUMPING STATION #1 PUMPING STATION 2 -6 INSTALL 2" PVC PIPE FOR PLASTIC HOSE. PUMPS: FLYGT CG -3065 3" PUMPS: SMITH &LOVELESS 4B2 2-7 FURNISH NEW 12 GA. STEEL WEATHER RESISTANT ENCLOSURE 150 G.P.M. ® 17' T.D.H. 350 G.P.M. ® 14' T.D.H. (NEMA TYPE 3) PRIMED AND PAINTED FOR 55- GALLON DRUMS PER ESSCO OR EQUAL. BOTTOM TO BE ON ROLLERS AND HAVE MOTORS: 2 H.P., 3300 RPM MOTORS: 3 H.P., 1160 RPM ANCHOR BOLTS PER ESSCO STANDARD DESIGN. 440 V, 3 PHASE 240 V, 3 PHASE 2 -8 REPLACE LANDSCAPING REMOVED DURING CONSTRUCTION WITH IMPELLER NO. 203 EQUAL OR AS REQUESTED BY SOUTH COAST PLAZA. INSTALLED: 1965 -66 INSTALLED: 1974 2-9 REMOVE ANY EXIST. RUST AND CORROSION, THEN APPLY PRIMER AND PAINT TO EXIST. ENCLOSURE PER DISTRICT REQUIREMENTS. PROPOSED PUMPING STATION: F2---1-0-1 REMOVE EXIST. WATER LEVEL WELL AND INSTALL NEW PUMPS: FLYGT CP -3102 6" WATER LEVEL WELL PER DETAIL "C" 495 G.P.M. ® 22' T.D.H. NOTES: MOTORS: 5 H.P., 1700 R.P.M. 460 V, 3 PHASE 1. ALL EXISTING EQUIPMENT REMOVED AS PART OF WORK TO BE DELIVERED TO INSTALLATION - 1991 CITY CORPORATION YARD, 2300 PLACENTIA AVE., COSTA MESA SANITARY DISTRICT COSTA MESA 2. PLANS OF THE EXISTING PUMPING STATIONS PROJECT NO. 1112100 -118 W R TABLE REHABILITATION OF ARE AVAILABLE FOR REVIEW AT THE SOUTH COAST PLAZA DISTRICT ENGINEER'S OFFICE, (714) 631 -1731. IT IS SUGGESTED THAT THESE PLANS BE PUMPING STATIONS REVIEWED BY ALL BIDDERS.