S-91-1.3 (2)Y
W
a
n
c
U
J
W
/
A ,
4
co
co
cr
OD to Off•
Lb
N w Q, / <C�`�'' L= 40.46' �' v A
+ 3 i /'/ �Q` �� N 46'37'57" E /% A X V A
C114 v \X
O
83 60 �� S 45 48 5
4 `
4 � �
SEWER CONSTRUCTION NOTES
LEGEND:
OF
COSTA
MESA
DEPARTMENT OF
PUBLIC
30. CONSTRUCT
6" VCP LATERAL PER C.M.S.D. STD. DWG. NO. S -104 -A
T.C.
TOP OF CURB ELEVATION
& S -104 -D
F.S.
FINISHED SURFACE ELEVATION
S
F. L.
FLOW LINE ELEVATION
CONSTRUCT
6" PVC LATERAL PER MODIFIED C.M.S.D. STD.
F.G.
FINISH GROUND ELEVATION
DWG. NO. S-
104 -A.
SHEET MATCH LINE
- - --
TRACT BOUNDARY
32. CONSTRUCT
6" CLEANOUT C.M.S.D. STD. DWG. NO. S -107.
FF =XX.XX FINISHED FLOOR ELEVATION
41 ` \ 4 �s `,yam S�PGI�F� PAD =XX.X PAD ELEVATION 33. REMOVE EXISTING UTILITIES. ALL EXISTING MN FRAMES & COVERS TO BE
(xx.xx) EXISTING ELEVATION
41 H.P. HIGH POINT ELEVATION DELIVERED TO CITY CORPORATION YARD (2300 PLACENTAI AVE)
QP. i y -'� �� ❑N VAULT
1 A ` ���
% -- DIRECTION of rl oW 34 REPLACE CONCRETE PAVEMENT AND TRENCH PER CITY OF
�N `Tt
v
o
XX.X
�> DIA..,P STIC RIIDE EXISTING SPOT ELEVATION COSTA MESA STD. DWGS. NO. 812 AND 813.
\ r :: 5
RIDGE LINE
G.B. GRADE BREAK
BAC OW 3 Q�� 10 `y` T.W. TOP OF WALL
- DEVIC 4 1 T.F. TOP OF FOOTING
3 '' , 4 /'/ ;' \ 6`'�` -� tiNDfll -AT -LS 2:1 SLOPE WATER CONSTRUCTION NOTES
3 2 +75 r3 \ \ P�x rlO� - I-B•s•l• BUILDING SETBACK LINE
F -91.31 5 5� - - - EXISTING SEWER
5
y ` s ti, F - - - -- EXISTING WATER INSTALL 2" WATER SERVICE ASSEMBLY PER
41. M.C.W.D. STD. DWG. NO. 2.
/- o �, �� 90 - -G -- EXISTING GAS
\ SEWER
WATER
42. INSTALL WATER METER PER M.C.W.D. STD. DWG. NO. 3 & 1 6.(SEE TABLEON SHEET NO. 1 )
EXISTING ,
o- WATER METER
ABANDONED FIRE HYDRANT
CAP EAT P /ERAL s 45 \ �Xp \ CLEAN OUT 43. INSTALL 3-2" WATER SERVICES IN COMMON TRENCH.
45 O �k ELEVATION PER ARCHITECTS PLAN
` ® REMOVE AND REPLACE A.C. WITH
4 \ lS'J, 6" A.C. 118" C.M.B. 44. INSTALL 6 „ DOUBLE CHECK VALVE BACKFLOW PREVENTER PER
EXISTING STEEL POST M.C.W.D. STD. DWG. NO. 17)W/ 5/8" BYPASS METER IN CUBIC FEET.
J tx EXISTING STREET LIGHT
� 6 � %9 � v � ��� �� EXISTING EDISONETAULT 45. INSTALL 6" P,V.C. PER M.C.W.D. STDS. (CLASS 150, AWWA, C900 WHITE).
GQ EXISTING WATER VALVE
\�i� `� QS EXISTING ELECTRIICSVAULL VAULT 46. INSTALL FIRE HYDRANT ASSEMBLY PER M.C.W.D. STD. DWG. NO. 4.
EXISTING WATER METER (WET BARREL)
,- EXISTING AIR VAC
/ �J► \ / f
EXISTING TREE 47. REPLACE CONCRETE PAVEMENT AND TRENCH PER CITY OF
EXISTING GUYWIRE COSTA MESA STD. DWGS. NO. 812 AND 813.
SEE DETAIL x�p
4 \
FOR SEWER 48. INSTALL 6" RT. 45 DEGREE ELBOW WITH THRUST BLOCK PER
-- - - - -- - -f -
CONNECTION M.C.W.D. STD. DWG. NO. 12.
4
3 41 v DETAIL 49. INSTALL 6" RT. 90 DEGREE ELBOW WITH THRUST BLOCK PER
- 3 k\ �� N. .s. M.C.W.D. STD. DWG. NO. 12.
a9 �SZ EXIST 8" VCP SEWER - _ _ 5 %IG. 45+86.39 INSTALL 6r WYE „ „
_----- _._ - - - -- _ - -- �r� _ _ __- _._........ .. ........ . . .- _ _ - -_, Ern\ INSTALL 16" X 6 HOT TAP WITH 6 R.W. VALVE PER M.C.W.D. STD.
E ST 8• VCP SEWER 50' DWG. NO. 5 OR 6.
RELOCATE EXISTING FIRE HYDRAN T. (DR Y BARR EL) PE R DIST STD DWG. N0. 4.
EXIST SEWER SERVICE
r.
93.51 FF =93. @B
n
[FI FF =92.9 FF 92.63
_ 1
INSTALL CASING PER M.C.W.D. STD. DWG. NO. 10 MODIFIED FOR
52.
CLEANOUT OPEN CUT.
v
R= 28.00' \\\ ` INSTALL 5' WYE 53. INSTALL 1 1/2" WATER METER PER M.C.W.D. STD. DWG. NO. 3 & 16.(IRRIGATION)
L =7.97'
INSTALL THRUST BLOCK PER DIST. STD. DWG. NO. 12.
Ell
\ \\ \ .
55. RELOCATE EXISTING 2" AIR VAC PER M.C.W.D. STD. DWG. NO. 8.
31
FF =91.46
o ❑ •DIA PLASTIC PIPE ADJUST TO GRADE & PROTECT AS NEEDED.
FF =92.13 o R= 42.00' �° \
o L -7.71' ISDN VAULT 57. INSTALL 8" x 6" A.C. x. FLG. 45' ELL W/ 6" R.W. VALVE.
PLASTIC PIPE
o s \
0.
o �3 `.� INDICATES PRIVATE ONSITE WATER
o
❑ 0 31
'�` `5' \ O INDICATES PUBLIC OFFSITE WATER
�
o�
. 31 ,
- -- - - -
_ ......... tab
1
CALTRANS RIGHT -OF -WAY
\ I
CONSTRUCTION C/L
45
OQ(20FES$/ PA -88 -131
101+00 102 +00 103 +00 104 +00 105 +00 1 6 +00 107 +00 107 +21.93
- - -- -- � C/L OF RECORD T- �- - - - T� - -� - - LU 31ro imai Aw.c • cmrA 0�s n14) W�
FIRE No. C 33292 w IW LIVk EWMEEMq o WW wo Mf 7TM9
101 +525 NEWPORT SOUL VARD
_ FIRE HYDRANT _
4-- FLOWER ST. _
REVISIONS CONTRACTOR REFERENCES
NO. DATE DESCRIPTION APP. BENCH MARK N0. REFERENCE PLANS
ELEVATION NOTE TO CONTRACTOR
WORK STARTED:
DESCRIPTION STANDARD DRAWING NO.
WORK ACCEPTED:
INSPECTED BY:
DESIGNED BY:
DRAWN BY:
DATE CHECKED BY:
CHECKED BY:
DATE
s Exp.06/30/94
FOF CALIFO`�
SEWER AND WATER PLANS
TRIANGLE SQUARE
PREPARED UNDER THE SUPERVISION OF:
�o -Jo -fa
JAMES R. MAIT ND R.C.E. 33292 DATE
3
SHEET
OF
4
PLAN
NUMBER
CITY
OF
COSTA
MESA
DEPARTMENT OF
PUBLIC
SERVICES / ENGINEERING DIVISION
I A I A 4 r) r)