S-91-1.1GENERAL SEWER NOTES 1. THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE CITY OF COSTA MESA SANITARY DISTRICT. L CONTRACTOR SHALL REQUEST INSPECTION FROM THE OFFICE OF THE DISTRICT ENGINEER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. TELEPHONE: (714) 631 -1731. 3. ANY WORK PERFORMED WITHOUT INSPECTION FROM THE DISTRICT SWILL BE CONSIDERED UNACCEPTABLE. 4. CONTRACTOR SHALL OBTAIN CMSD SEWER PERMIT PRIOR TO COMMENCEMENT OF WORK FROM THE DEPARTMENT OF STREETS AND SANITATION, CITY OF COSTA MESA, 77 FAIR DRIVE. TELEPHONE: (714) 754 -5323. S. CONTRACTOR SWILL OBTAIN ALL NECESSARY PERMITS THAT MAY BE REQUIRED BY THE LOCAL GOVERNING AGENCY. 0. CONTRACTOR TO HAVE A COPY OF APPROVED SEWER PLAN AND CMSD STANDARD PLANS AND SPECIFICATIONS ON JOB SITE AT ALL TIMES. 7. CLAY PIPE JOINTS SHALL BE TYPE •G" MECHANICAL COMPRESSION JOINTS FOR MAIN UNE SEWER. TYPE "D" JOINTS, BAND -SEAL OF APPROVED EQUAL, ARE APPROVED FOR LATERALS AND REPAIR WORK ONLY. 10. StAYP lr ON CURS AT SEWER LATERAL LOCATIONS. M.C.W.D. STANDARD WATER CONSTRUCTION NOTES 1. ENGINEERING PUN CHECK /INSPECTION FEE AND PERFORMANCE GUARANTEE BOND SHALL BE PAID AND APPLICATION /PERMIT (A.P.) COMPLETED BY THE APPLICANT PRIOR TO THE APPROVAL OF THE PLANS AND ISSUANCE OF THE A.P. FEES SHALL BE IN ACCORDANCE WITH DISTRICT RATES AND DEPOSIT SCHEDULE. 2. DEVELOPMENT IMPACT FEES SHALL BE COLLECTED BY THE DISTRICT AT THE TIME OTHER FEES ARE COLLECTED PRIOR TO APPROVAL OF PUNS OR SERVICE AGREEMENT, WHICHEVER IS FIRST. THIS FEE SHALL BE IN ACCORDANCE WITH DISTRICT RATES AND DEPOSIT SCHEDULE. 3. WATER MAINS WILL BE INSTALLED ACCORDING TO THE LATEST STANDARDS AND SPECIFICATIONS OF THE MCWD. 4. CONTRACTOR TO HAVE, ON THE JOB SITE, A COPY OF THE LATEST STANDARD SPECIFICATIONS AT ALL TIMES. I. CONTRACTOR TO NOTIFY MCWD 48 HOURS PRIOR TO CONSTRUCTION (PHONE: 714/754 -5398 INSPECTION DEPARTMENT). 6. A PERFORMANCE GUARANTEE BOND SHALL BE HELD ONE YEAR AFTER - MCWD'S NOTICE OF COMPLETION TO GUARANTEE WORK PERFORMED BY THE CONTRACTOR. 7. SEPARATION BETWEEN SANITARY SEWER AND WATER MAINS WILL BE 10' HORIZONTAL, 1' VERTICAL. 6. A 15' WATER MAIN EASEMENT WILL BE GRANTED TO THE MCWD FOR MAINTENANCE PURPOSES, 5' FOR WATER SERVICES (7.5' EACH SIDE OF MAIN; 2.5' EACH SIDE OF SERVICE). EASEMENT DOCUMENTS ARE TO BE SUBMITTED TO THE DISTRICT NO LATER THAN _30- DAYS AFTER NOTICE OF COMPLETION IS FILED. 9. SERVICE LATERALS WILL BE SET TO GRADE BY CONTRACTOR PRIOR TO THE INSTALLATION OF WATER METERS AND BOXES (PER MCWD'S STANDARD DRAWINGS #1, #2 AND #3). 10. WATER METER WILL NOT BE INSTALLED NOR WATER TURNED ON UNTIL THE BACKFLOW DEVICES REQUIRED FOR THE BUILDING AND IRRIGATION SYSTEMS HAVE BEEN INSTALLED, TESTED, APPROVED, AND CERTIFIED. CONTACT WATER QUALITY AT (714) 754 -5398. 11. PROTECT EXISTING UTILITIES IN PUCE. 12. WATER MAINS WILL HAVE 47' MINIMUM COVER TO FINISH GRADE. 13. RAISE EXISTING WATER VALVE COVERS TO GRADE (PER MCWD STANDARD DRAWING #14). 14. 96TALL FIRE HYDRANT PER MCWD STANDARD DRAWING /4. 15. INSTALL BLOW -OFF PER MCWD STANDARD DRAWING #9. 16. WATER MAINS WILL BE TESTED AT 225 P.S.I. FOR FOUR HOURS. 17. BACKFILL MATERIAL IN PIPE ZONE WILL HAVE A SAND EQUIVALENT OF 30 OR GREATER. REVISIONS TRIANGLE SQUARE SEWER &WATER PLANS CHIP OUT BASE OF EXISTING MANHOLE AND RECONSTRUCT NEW SMOOTH CHANNEL AS REQUIRED BY COSTA MESA SANITARY DISTRICT INSPECTOR. WORK REQUIRES BY -PASS OPERATION TO REMOVE SEWER FLOWS, OR AS OPTION, CONTRACTOR MAY PERFORM WORK IN EARLY MORNING HOURS IF FLOW IS LOW ENOUGH. EXISTING 8" VCP SEWER 19TH STREET EXIST. 1?• VCP SEWER OFF -SITE SEWER CONSTRUCTION 18. THE BACKFILL ABOVE THE PIPE ZONE WILL BE COMPACTED PER MCWD STANDARD DRAWING #18, AND BE W COMPLIANCE WITH C.C.Y. STANDARD DRAWING 813. 19. CHIP Y •W IN CURB FACE TO IDENTIFY WATER SERVICE LOCATION. 20. INSTALL THRUST BLOCKS PER MCWD DISTRICT STANDARD DRAWING #12. 21. CONTRACTOR TO VERIFY DEPTH AND LOCATICN OF ALL UTILITIES PRIOR TO TRENCHING. 22. CONTRACTOR TO INSTALL TEMPORARY TAPS FOR TESTING AND CHLORINATION PRIOR TO CONNECTING TO EXISTING MAINS. 23. CONTRACTOR TO RETURN ALL MATERIAL REMOVED TO MCWD YARD, EXCEPT A.C.P., BROKEN CONCRETE, AND NATIVE SOIL 24. WATER METERS AND BOXES TO BE INSTALLED BY MCWD BUT PAID FOR BY OTHERS. 25. A DOUBLE CHECK VALVE ASSEMBLY WILL BE REQUIRED ON ALL WATER METERED SERVICES TO ANY CONDOMINIUM UNIT OVER TWO STORIES OR FIVE OR MORE UNITS ON ONE METERED SERVICE. CONTACT WATER QUALITY AT (714) 754 -5398. 26. IRRIGATION METERS WILL REQUIRE A REDUCED PRESSURE PRINCIPLE ASSEMBLY. 27. A REDUCED PRESSURE PRINCIPLE ASSEMBLY WILL BE REQUIRED ON METERED WATER SERVICES TO ALL INDUSTRIAL BUILDINGS. 28. A DOUBLE CHECK VALVE ASSEMBLY WILL BE REQUIRED ON METERED WATER SERVICES TO ALL COMMERCIAL BUILDINGS. 29. IN LANDSCAPED AREAS, 0 TREES SHALL BE LOCATED IN MCWO EASEMENT OR WITHIN 7.5' OF ANY MCWD FACILITY. 30. FIRE LINES WILL NOT BE TURNED ON UNTIL THE DISTRICT ENGINEERING DEPARTMENT HAS RECEIVED A LETTER FROM THE OWNER OR HIS AUTHORIZED AGENT TO DO SO. THE LETTER WILL CONTAIN THE FILE NUMBER, JOB ADDRESS, SIZE OF DEVICE, AND ASSIGNED SERIAL NUMBER. CONTRACTOR WORK STARTED: WORK ACCEPTED: INSPECTED BY. DATE BENCH MARK NO. ELEVATION LEGEND* T.C. TOP OF CURS ELEVATION F.S. FINISHED SURFACE ELEVATION F.L. FLOW LINE ELEVATION F.G. FINISH GROUND ELEVATION ft� SHEET MATCH LINE ftm m w � TRACT BOUNDARY FF -XX.XX FINISHED FLOOR ELEVATION PAD -XX.X PAD ELEVATION (XX.XX) EXISTING ELEVATION H.P. HIGH POINT ELEVATION '�--- DIRECTION OF FLOW )klcX EXISTING SPOT ELEVATION /: � RIDGE LINE C.B. GRADE BREAK T.W. TOP OF WALL T.F. TOP OF FOOTING T T INDICATES 2:1 SLOPE .ict.S,L BUILDING SETBACK LINE DELIVERED TO CITY CORPORATION YARD 2300 PLACENTIA AVE. EXISTING SEWER "-- -- EXISTING WATER -- -G-- EXISTING GAS M.C.W.D. STD. DWG. NO. 12. SEWER WATER O- WATER METER ♦ FIRE HYDRANT • CLEAN OUT �k ELEVATION PER ARCHITECTS PLAN INSTALL 16" X 6" HOT TAP WITH 6" R.W. VALVE PER M.C.W.D. STD. D REMOVE AND REPLACE A.C. a EXIST. STEEL POST DWG. NO. 5 OR 6. EXIST. STREET LIGHT EXIST. GAS METER 'E EXIST. EDISON VAULT s EXIST. WATER VALVE 91 EXIST. ELECTRIC VAULT Tv EXIST. TRAFFIC SIGNAL VAULT 0 EXIST. WATER METER L EXIST. AIR VAC INSTALL 1-1/2- WATER METER PER M.C.W.D. STD. DWG. NO. 3 & 16. CONSTR & QUANTITIES: ITEM I DESCRIPTION QUANTITY, UNIT SEWER CONSTRUCTION NOTES ONSITE OFFSITE 30. CONSTRUCT 6" VCP LATERAL PER C.M.S.D. ST6 DWG. NO. S -104 -A 44. I INSTALL 6" DOUBLE CHECK VALVE BACKFLOW PREVENTER PER do S -104 -D 1do LF 31. CONSTRUCT 6" PVC LATERAL PER MODIFIED C.M.S.D. STD. 45. I INSTALL 6" PVC. PER M.C.W.D. STDS. (CLASS 150, AWWA, C900 WHITE). 7 725 DWG. NO. S- 104 -A. 1200 LF 32. CONSTRUCT 6" CLEANOUT C.M.S.D. STD. DWG. NO. S -107. 16 EA REPLACE CONCRETE PAVEMENT AND TRENCH PER CITY OF REMOVE EXISTING UTILITIES. ALL EXISTING SEWER MH FRAMES do COVERS TO BE COSTA MESA STD. DWGS. NO. 812 AND 813. 33. DELIVERED TO CITY CORPORATION YARD 2300 PLACENTIA AVE. a INSTALL 6" RT. 45 DEGREE ELBOW WITH THRUST BLOCK PER 2 EA 34. REPLACE CONCRETE PAVEMENT AND TRENCH PER CITY OF M.C.W.D. STD. DWG. NO. 12. 520 49. I COSTA MESA STD. DWGS. NO. 812 AND 813. I SF WATER CONSTRUCTION NOTES ONSITE OFFSITE 41. INSTALL 2" WATER SERVICE ASSEMBLY PER M.C.W.D. STD. DWG. 'NO. 2. ilD 42. INSTALL WATER METER PER M.C.W.D. STD. DWG. NO. 3 do 16. ,c - ( ( SIZE PER TABLE BELOW) 43. I INSTALL 3 -2" WATER SERVICES IN COMMON TRENCH. 44. I INSTALL 6" DOUBLE CHECK VALVE BACKFLOW PREVENTER PER M.C.W.D. STD. DWG. NO. 17 W/ 5/8" BYPASS METER IN CUBIC FEET. 45. I INSTALL 6" PVC. PER M.C.W.D. STDS. (CLASS 150, AWWA, C900 WHITE). 7 725 46. I INSTALL FIRE HYDRANT ASSEMBLY PER M.C.W.D. STD. DWG. NO. 4. WET BARREL 47. R REPLACE CONCRETE PAVEMENT AND TRENCH PER CITY OF COSTA MESA STD. DWGS. NO. 812 AND 813. 48. I INSTALL 6" RT. 45 DEGREE ELBOW WITH THRUST BLOCK PER 2 2 M.C.W.D. STD. DWG. NO. 12. 49. I INSTALL 6" RT. 90 DEGREE ELBOW WITH THRUST BLOCK PER I I M.C.W.D. STD. DWG. NO. 12. S I INSTALL 16" X 6" HOT TAP WITH 6" R.W. VALVE PER M.C.W.D. STD. D DWG. NO. 5 OR 6. 51. R RELOCATE EXISTING FIRE HYDRANT, (DRY BARREL) PER DIST. STD. DWG. NC! 4 52 I INSTALL CASING PER M.C.W.D. STD. DWG. NO. 10 'MODIFIED FOR OPEN CUT. 53. I INSTALL 1-1/2- WATER METER PER M.C.W.D. STD. DWG. NO. 3 & 16. IRRIGATION SEE TABLE BELOW 54. I INSTALL THRUST BLOCK PER DIST. STD. DWG. NO. 12. 55. R RELOCATE EXISTING 2" AIR VAC PER M.C.W.D. STD. DWG. NO. 8. 56. A ADJUST TO GRADE do PROTECT AS NEEDED. 57. I INSTALL 8" x 6" A.C. x FLG. 45" ELL W/ 6" R.W. VALVE. INDICAT P ES RIVATE ONSITE WATER O INDICATES PUBLIC OFFSITE WORK RESTURAUNT FOOD COURT SEWER NOTES: FOOD COURT CINEMA ALL NEW ON -SITE SEWER IS PRIVATE AND TO BE INSPECTED BY CITY OF MARKET COSTA MESA BUILDING DEPT. 754 -5290 POSSIBLE RESTURANT ALL NEW SEWER IN HARBOR BLVD. & 19TH STREET R/W TO BE RESURANT INSPECTED BY THE COSTA MESA SANITARY DISTRICT (714) 631 -1731 MALL ALL EXISTING SEWER TO BE REMOVED TO BE INSPECTED BY COSTA MALL MESA SANITARY DISTRICT (714) 631 -1731. CONTACT DISTRICT FOR IRRIGATION ADDITIONAL INFORMATION ON EXISTING SEWER LATERAL LOCATIONS; THIS PLAN SHOWS EXISTING MAIN LINES ONLY. "COMMERCIAL DEVELOPMENT" 3 1 3 40 `i rl 1 A 3 2 V] 1 d i:A EA EA 1 EA LF EA SF EA T_ EA EA EA EA EA EA 71 r� WATER METER DEMAND METER NO. SIZE FIXTURE UNITS GPM W1 II/2" 210 92 W2 I" 120.5 50 W3 I" 120.5 50 W4 II /2', 250 98 W5 II /2" 125 79 W6 1" 125 45 W7 II/2" 210 92 W8 II/2" 213 82.5 W9 1 II/2" 1 213 1 82.5 W10 11 Iltl IRRIGATION 1 40 INFORMATION PROVIDED BY DOUBLE "O" ENGINEERING SEE PLUMBING PLANS FOR DET EXIST. TREE �- EXIST. GUYWIRE ��O �FP�/ %tom JOB ADDRESS: 1850 NEWPORT BLVD. PPREF MES A CONSOLIDATED WATER DISTRICT No. C 33292 _ _ _ MC 1 1 17 END. 0513U/94 FTAmM O UNDER T E SAUPERVIS 01 N FOO f /- R. MATT D R. .33292 DATE APPROVED BY DA REFERENCES DESIGNED BY: DATE CHECKED BY: DATE f� DRAWN BY: CHECKED BY: TITLE SHEET REFERENCE PLANS ■ RIANGLE SQUARE NOTE TO CONTRACTOR T STANDARD DRAWING ND. SEWER & WATER PLANS 24c -Isar. CITY ENGINEER R.C.E. COSTA MESA SANITARY DISTRICT APPROVED FOR CONSTRUCTION WITHIN HARBOR BLVD. k 19TH STREET R/W ONLY DISTRICT ENGINEER DATE SHEET OF 4 PLAN NUMBER CITY OF COSTA MESA DATE DEPARTMENT OF PUBLIC SERVICES / ENGINEERING DIVISION J N -A 19.9 4 EXIST. TREE �- EXIST. GUYWIRE ��O �FP�/ %tom JOB ADDRESS: 1850 NEWPORT BLVD. PPREF MES A CONSOLIDATED WATER DISTRICT No. C 33292 _ _ _ MC 1 1 17 END. 0513U/94 FTAmM O UNDER T E SAUPERVIS 01 N FOO f /- R. MATT D R. .33292 DATE APPROVED BY DA REFERENCES DESIGNED BY: DATE CHECKED BY: DATE f� DRAWN BY: CHECKED BY: TITLE SHEET REFERENCE PLANS ■ RIANGLE SQUARE NOTE TO CONTRACTOR T STANDARD DRAWING ND. SEWER & WATER PLANS 24c -Isar. CITY ENGINEER R.C.E. COSTA MESA SANITARY DISTRICT APPROVED FOR CONSTRUCTION WITHIN HARBOR BLVD. k 19TH STREET R/W ONLY DISTRICT ENGINEER DATE SHEET OF 4 PLAN NUMBER CITY OF COSTA MESA DATE DEPARTMENT OF PUBLIC SERVICES / ENGINEERING DIVISION J N -A 19.9 4 J N -A 19.9 4