S-2000-1.1V 5� 1 i °s F W LL i a L GENERA. NOTES FOR 9FFSIT6 MIPROVEMENT PLAN 1. ALL WORK AND MATERIALS WITHIN THE PUBLIC RIGHT -OF -WAY SHALL CONFORM TO THE CITY OF COSTA MESA STANDARDS. THE CONDITIONS OF APPROVAL AS APPROVED ON AUGUST 21, 2000, AND SHALL MEET THE APPROVAL OF THE CITY ENGINEER. 2. ALL WORK SHALL BE PERFORMED AND ALL MATERIALS SHALL BE IN ACCORDANCE WITH CITY OF COSTA MESA STANDARD DRAWINGS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, (GREEN BOOK) CURRENT EDITION. 3. CONTRACTOR SHALL FURNISH AND INSTALL ALL SIGNS, LIGHTS, BARRICADES, FLASHING ARROW BOARD AND ANY OTHER TRAFFIC CONTROL OR WARNING DEVICES, INCLUDING FLAGMEN, AS MAY BE REQUIRED BY THE CITY ENGINEER. ALL ITEMS MENTIONED SHALL BE IN CONFORMANCE WITH THE CURRENT REQUIREMENTS AS SPECIFIED IN THE LATEST EDITION OF THE "CONSTRUCTION SAFETY ORDERS," AND W.A.T.C.H. FAILURE TO DO SO WALL BE CITED UNDER APPLICABLE SECTION OF THE C.V.C. AND CORRECTIVE COSTS TO THE CITY WALL BE CHARGED. 4. CONTRACTOR SHALL OBTAIN PUBLIC SERVICES DEPARTMENT EXCAVATION AND CONSTRUCTION ACCESS PERMITS PRIOR TO START OF ANY ON- OR OFF -SITE CONSTRUCTIONS IN PUBLIC RIGHT -OF -WAY AND REQUEST INSPECTION FROM CITY PUBLIC SERVICES DEPARTMENT 24 HOURS IN ADVANCE OF PERFORMING ANY WORK. TELEPHONE (714) 754 -5025, THE CONTRACTOR SHALL MAINTAIN A COPY OF PERMITS AND SIGNED PLANS ON THE JOB SITE. 5. PERMITS WALL BE REQUIRED FROM THE MESA CONSOLIDATED WATER DISTRICT, ORANGE COUNTY SANITATION DISTRICT, AND COSTA MESA SANITARY DISTRICT FOR CONSTRUCTION OF WATER AND SEWER IMPROVEMENTS. THE CONTRACTOR SHALL NOTIFY EACH 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. 6. GEOLOGIC AND /OR SOILS REPORTS PREPARED BY PACIFIC SOILS AND DATED OCTOBER 27, 1999, HAVE BEEN REVIEWED AND APPROVED BY THE BUILDING OFFICIAL INCLUDING ALL SUPPLEAWINTS, ADDENDA, AND AMENDMENTS THERETO ARE INCLUDED BY REFERENCE. COPIES OF THESE REPORTS ARE ON FILE AT THE CITY PUBLIC WORKS DEPARTMENT. ALL RECOMMENDATIONS CONTAINED THEREIN MUST BE FOLLOWED. 7. THE CONTRACTOR SHALL PAY FOR THE INITIAL SOIL AND MATERIALS TESTS AND ANY SUBSEQUENT SOIL AND MATERIALS TESTS DEEMED NECESSARY, DUE TO THE FAILURE OF THE INITIAL TESTS. AS DETERMINED BY THE CITY ENGINEER. S. PAVEMENT AND BASE THICKNESSES AS SHOWN ARE BASED ON A PRELIMINARY "R" VALUE. DURING CONSTRUCTION A SOILS TEST SHALL BE MADE TO DETERMINE THE ACTUAL "R" VALUE AND THE THICKNESSES WILL BE ADJUSTED ACCORDINGLY. TESTS SHALL BE MADE BY A LICENSED SOILS ENGINEER AND APPROVED BY THE CITY ENGINEER. 9. LOCATE AND PROTECT ALL EXISTING UTILITIES IN PLACE. SUBMIT NOTIFICATION LETTER ALONG WITH PLANS TO SOUTHERN CALIFORNIA EDITON, PACIFIC BELL, AND SOUTHERN CALIFORNIA GAS COMPANY PRIOR TO APPROVAL OF PLAN. 10. ALL CONSTRUCTION STAKING SHALL BE DONE BY A LICENSER ENGINEER AND CERTIFIED IN WRITING AS TO LINE AND GRADE PER APPROVED PLAN AND SUBMITTED TO THE CITY ENGINEER. 11. NO WORK SHALL BE DONE ON ADJACENT PROPERTIES OR ADJACENT OWNERS IMPROVEMENTS WITHOUT OBTAINING WRITTEN PERMISSION FROM THE OWNERS OF THE ADJACENT PROPERTIES, AND SUBMITTING A COPY THEREOF TO CITY ENGINEERING DIVISION AND BUILDING DEPARTMENT, jj 12. WORK, ONCE BEGAN, SHALL BE PROSECUTE TO COMPLETION WITHOUT DELAY SO AS TO PROVIDE MINIMU *M* INCONVENIENCE TO ADJACENT PROPERTY OWNERS AND THE TRAVELING PUBLIC. 13. ALL STREET STATIONING REFERS TO THE CENTER LINE OF THE STREET AND CURB DATA REFERS TO THE FACE OF THE CURB. 14. THE AMOUNT OF ASPHALT BINDER TO BE MIXED WITH THE MINERAL AGGREGATE SHALL BE 5.6 PERCENT BY DRY WEIGHT. 15. ALL UNDERGROUND WORK SHALL BE COMPLETE PRIOR TO ANY SURFACE WORK IN THE PUBLIC RIGHT -OF -WAY. 16. CRUSH MISCELLANEOUS BASE MAY BE USED UNDER WALKS AND CURB AND GUTTER IN LIEU OF CRUSHED AGGREGATE BASE. 17. ANY LOT CORNER OF OCEMA BM, MONUMENT, OR TIE DESTROYED OR DISPLACED SHALL BE RESTORED TO ITS ORIGINAL POSITION BY A LICENSED. ENGINEER OR SURVEYOR. ANY CHANGE IN LOCATION OR ELEVATION SHALL BE REPORTED TO THE CITY ENGINEER AND OCEMA BY A LICENSED ENGINEER OR LAND SURVEYOR ON 8 -1/2" X 11" PAPER (ONE SIDE ONLY) SHOWING LOCATION AND TIES OR LEVEL RUN. 18. ALL EXISTING DRAINAGE COURSES ON THE PROJECT MUST CONTINUE TO FUNCTION, ESPECIALLY DURING STORM CONDITIONS, AND APPROVED PROTECTIVE MEASURES AND TEMPORARY DRAINAGE PROVISIONS MUST BE USED TO PROTECT ADJOINING PROPERTIES DURING THE GRADING PROJECT. IN ALL CASES, THE CONTRACTOR AND/OR DEVELOPER SHALL BE "ELD LUABLE FOR ANY DAMAGE DUC TO OBSTRUCTION OF NATURAL DRAINAGE PATTERNS. IF THE FOREGOING CANNOT BE COMPLIED WITH, A FULLY EXECUTED, NOTARIZED, AND RECORDED AGREEMENT BETWEEN THE AFFECTED PARTIES WILL BE AFFECTED. 19. ALL HAUL ROUTES MUST BE APPROVED BY THE MANAGER OF TRANSPORTATION SERVICES. MPORTANT NOTICE SECTION 4216 /4217 OF THE GOVERNMENT CODE REQUIRES A DIGALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A "PERMIT TO EXCAVATE" WILL BE VALID. FOR 'YOUR DIGALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1- 80G- 227 -26000 TWO WORKING DAYS BEFORE YOU DIG cc REVISIONS NM DATE DEM RPTION AM. ADDED WATER METERS AND MOVED BACKFLOW DEVICES CLOSER TO BUILDING DA ADPW IRRIGATION MAET'EQ5 ON MEg^ VERDE DRIVE. DA IMPROVEMENT PLANS 20. THE PROJECT SITE SHALL BE MAINTAINED IN A 'WET -DOWN' CONDITION TO PREVENT EXCESSIVE DUST. SPILLAGE AND DUST SHALL BE REMOVED FROM THE PUBLIC RIGHT -OF -WAY BY SWEEPING OR SPRINKLING; HOWEVER, WATERING, THAT RESULTS IN MUD ON PUBLIC STREETS IS NOT PERMITTED AS A SUBSTITUTE FOR OTHER CLEANING METHODS. 21. ALL UTILITY TRENCH BACKFILL, MATERIAL, AND COMPACTION SHALL CONFORM TO CCM STANDARD NO. 813. BORE UNDER EXISTING IMPROVEMENTS - TUNNELING IS NOT ALLOWED. NO OPEN EXCAVATIONS WILL BE ALLOWED OVERNIGHT - BACKFILL OR PLATE, 22. ALL PCC AND AC TO BE JOINED SHALL BE SAWCUT IN A CLEAN, STRAIGHT LINE AS APPROVED BY THE CITY ENGINEER. 23. "AS- BUILT' DRAWINGS SHALL BE SUBMITTED TO THE CITY ENGINEERING DIVISION UPON COMPLETION OF IMPROVEMENTS AS SHOWN ON THE APPROVED PLANS. STANDARD WATER CONSTRUCTION NOTES 1. ENGINEERING PLAN CHECK/INSPECTION FEE AND PERFORMANCE GUARANTEE BOND SHALL 14. INSTALL FIRE HYDRANT PER MCWD STANDARD DRAWING #4 OR 044 A DOUBLE CHECK DETECTOR ASSEMBLY WILL BE REQUIRED ON FIRE LINE SERVICES. FIRELINE SERVICES SHALL NOT BE TURNED ON UNTIL THE DISTRICT ENGINEERING DEPARTMENT HAS RECEIVED A LETTER FROM THE OWNER, OR HIS AUTHORIZED AGENT, REQUESTING IT AND STATING THAT THE PLUMBING IS READY FOR THE FIRELINE TO BE TURNED ON. THE LETTER MUST ALSO CONTAIN THE MCWD FILE NUMBER, SIZE AND SERIAL NUMBER OF THE DEVICE, AND JOB ADDRESS. CUM STANDARD SEWER NOTE9 THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE COSTA MESA SANITARY DISTRICT, CONTRACTOR SHALL REQUEST INSPECTION FROM THE OFFICE OF THE DISTRICT ENGINEER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. TELEPHONE: (949) 631 -1731. ANY WORK PERFORMED WITHOUT INSPECTION FROM THE DISTRICT SHALL BE CONSIDERED UNACCEPTABLE. CONTRACTOR SHALL OBTAIN CMSD SEWER PERMIT PRIOR TO COMMENCEMENT OF WORK FROM THE DEPARTMENT OF STREETS AND SANITATION, CITY OF COSTA MESA, 77 FAIR DRIVE. TELEPHONE: (714) 754 -5307 CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS THAT MAY BE REQUIRED BY THE LOCAL GOVERNING AGENCY. CONTRACTOR TO HAVE A COPY OF APPROVED SEWER PLAN AND CMSD STANDARD PLANS AND SPECIFICATIONS ON JOB SITE AT ALL TIMES. CLAY PIPE JOINTS SHALL BE TYPE "G" MECHANICAL COMPRESSION JOINTS FOR MAIN LINE SEWER. TYPE "D' JOINTS, BAND -SEAL OF APPROVED EQUAL, ARE APPROVED FOR LATERALS AND REPAIR WORK ONLY. 6" LATERALS SHALL BE CONSTRUCTED FROM THE SEWER MAIN TO EVERY LOT. ALL LATERALS SHALL BE PLACED PRIOR TO SURFACING OF STREETS, STAMP 'r ON CURB AT SEWER LATERAL LOCATIONS. SEWER MAIN SHALL BE AIR OR WATER TESTED MEETING DISTRICT ENGINEER'S APPROVAL. PRIOR TO ASPHALT CONCRETE PAVING, MANHOLE FRAMES AND COVERS SHALL BE LEFT 6' BELOW FINISH GRADE. AFTER STREET SURFACING IS COMPLETED, FRAMES AND COVERS SHALL BE RAISED TO GRADE PER STD. DWG. NO. S -105. SEWER MANHOLE FRAME AND COVER SHALL BE LHAMBRA FOUNDRY A -1270, OR APPROVED EQUAL. COVER TO BE STAMPED "SEWER." SEWER MAIN SHALL BE BALLED AFTER ALL MANHOLE FRAMES AND COVERS HAW BEEN RAISED TO GRADE. PVC PIPE MAY BE USED ONLY WITN PRIOR APPROVAL FROM THE DISTRMT ENGINEER, IF MINIMUM SEPARATION DISTANCE BETWEEN SEWER AND WATER MAIN IS NOT MET, SPECIAL CONSTRUCTION REQUIREMENTS ARE TO BE USED PER STD. DWG. NO. S- 110 -A OR S- 110-8. DEVELOPER IS RESPONSIBLE FOR REPLACING ANY EXISTING LATERALS NOT FOUND IN FIELD OR FOUND TO BE DEFECTIVE. ALL TRENCH EXCAVATION AND PIPE BEDDING SHALL BE DONE PER STD. DWG. NO. S -112. A CLEAN OUT WILL BE REQUIRED FOR EACH LOT ON PRIVATE PROPERTY BETWEEN RESIDENCE AND EDGE OF THE STREET RIGHT -OF -WAY. 15. BE PAID AND APPLICATION/PERMIT (A.P.) COMPLETED BY THE APPLICANT PRIOR TO THE 5. 16. APPROVAL OF THE PLANS AND ISSUANCE OF THE A.P. FEES SHALL BE IN ACCORDANCE THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES LINES AND IMPROVEMENT PLAN SHEET INDEX WITH DISTRICT RATES AND DEPOSIT SCHEDULE. STRUCTURES WHETHER SHOWN OR NOT SHOWN ON THIS PLAN, AND SHALL BE RESPONSIBLE 17. BACKFILL MATERIAL IN PIPE ZONE WILL HAVE A SAND EQUIVALENT OF 30 OR GREATER. S. 2. DEVELOPMENT IMPACT FEES SHALL BE COLLECTED BY THE DISTRICT AT THE TIME OTHER FEES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN STREET LIGHT PULL BOX ARE COLLECTED PRIOR TO APPROVAL OF PLANS OR SERVICE AGREEMENT, WHICHEVER IS ON THIS PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR T.C. FIRST. THIS FEE SHALL BE IN ACCORDANCE WITH DISTRICT RATES AND DEPOSIT SCHEDULE. 7. 1 WATER MAINS WILL BE INSTALLED ACCORDING TO THE LATEST STANDARDS AND CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILI- 19. SPECIFICATIONS OF THE R+ICwC TIES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS. 20. INSTALL THRUST OR GRAVITY BLOCKS PER MCWD DISTRICT STANDARD DRAWING #11 OR #12. 8. 4. CONTRACTOR TO HAVE, ON THE JOB SITE, A COPY OF THE LATEST STANDARD SPECIFICATIONS THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED 21. AT ALL TIMES, 9• 56 CONTRACTOR TO NOTIFY MCWD 48 HOURS PRIOR TO CONSTRUCTION (PHONE: (949) 631 -1291 10. TOP OF WALL INSPECTION DEPARTMENT). THE U.S. DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF 22. CONTRACTOR TO INSTALL TEMPORARY TAPS FOR TES71NO AND CHLORINAIM PRIOR TO ft 6. A CASH PERFORMANCE GUARANTEE BOND SHALL BE HELD ONE YEAR AFTER MCWD'S NOTICE RESPONSIBLE FOR THE CONTRACTOR'S AND SUBCONTRACTORS COMPLIANCE WITH THE FEDERAL F.H. OF COMPLETION TO GUARANTEE WORK PERFORMED BY THE CONTRACTOR. 12. 7. SEPARATION BETWEEN SANITARY SEWER AND WATER MAINS WALL BE 10' HORIZONTAL, CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION 1' VERTICAL. PRACTICES, CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPON- FINISHED SURFACE 13. It A 15' WATER MAIN EASEMENT WALL BE GRANTED TO THE MCWD FOR MAINTENANCE INCLUDING SSAFETTY OF ALL PERSONS ANID PROPERTTYI,RAND THAT THHIIS REQUIREMENT SHALL FLOW ARROW PURPOSES, 5' FOR WATER SERVICES (7.5' EACH SIDE OF MAIN; 2.5' EACH SIDE OF SERVICE). APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONTRACTOR FURTHER 25. EASEMENT DOCUMENTS ARE TO BE SUBMITTED TO THE DISTRICT NO LATER THAN 30 DAYS 14. HIGH POINT AFTER NOTICE OF COMPLETION IS FILED. ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK 9. SERVICE LATERALS WILL BE SET TO GRADE BY CONTRACTOR PRIOR TO THE INSTALLATION OF 15. SEWER LINE WATER METERS AND BOXES (PER MCWD'S STANDARD DRAWINGS #1, #2 AND #3). THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD 26. IRRIGATION METERS WILL REQUIRE A REDUCED PRESSURE PRINCIPLE ASSEMBLY 16. 10. WATER METER WILL NOT BE INSTALLED NOR WATER TURNED ON UNTIL THE BACKFLOW AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. P.A. DEVICES REQUIRED FOR THE BUILDING AND IRRIGATION SYSTEMS HAVE BEEN INSTALLED, = -- ELECTRICAL LINE TESTED, APPROVED, AND CERTIFIED. CONTACT WATER QUALITY AT (949) 574 -1031. 17. 11. PROTECT EXISTING UTILITIES IN PLACE, 18. 12. WATER MAINS WILL HAVE 42" MMOMUM COVER TO FINISH GRADE. 19. 13. RAISE EXISTING WATER VALVE COVERS TO GRADE (PER MCWD STANDARD DRAWING #14). 14. INSTALL FIRE HYDRANT PER MCWD STANDARD DRAWING #4 OR 044 A DOUBLE CHECK DETECTOR ASSEMBLY WILL BE REQUIRED ON FIRE LINE SERVICES. FIRELINE SERVICES SHALL NOT BE TURNED ON UNTIL THE DISTRICT ENGINEERING DEPARTMENT HAS RECEIVED A LETTER FROM THE OWNER, OR HIS AUTHORIZED AGENT, REQUESTING IT AND STATING THAT THE PLUMBING IS READY FOR THE FIRELINE TO BE TURNED ON. THE LETTER MUST ALSO CONTAIN THE MCWD FILE NUMBER, SIZE AND SERIAL NUMBER OF THE DEVICE, AND JOB ADDRESS. CUM STANDARD SEWER NOTE9 THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE COSTA MESA SANITARY DISTRICT, CONTRACTOR SHALL REQUEST INSPECTION FROM THE OFFICE OF THE DISTRICT ENGINEER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. TELEPHONE: (949) 631 -1731. ANY WORK PERFORMED WITHOUT INSPECTION FROM THE DISTRICT SHALL BE CONSIDERED UNACCEPTABLE. CONTRACTOR SHALL OBTAIN CMSD SEWER PERMIT PRIOR TO COMMENCEMENT OF WORK FROM THE DEPARTMENT OF STREETS AND SANITATION, CITY OF COSTA MESA, 77 FAIR DRIVE. TELEPHONE: (714) 754 -5307 CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS THAT MAY BE REQUIRED BY THE LOCAL GOVERNING AGENCY. CONTRACTOR TO HAVE A COPY OF APPROVED SEWER PLAN AND CMSD STANDARD PLANS AND SPECIFICATIONS ON JOB SITE AT ALL TIMES. CLAY PIPE JOINTS SHALL BE TYPE "G" MECHANICAL COMPRESSION JOINTS FOR MAIN LINE SEWER. TYPE "D' JOINTS, BAND -SEAL OF APPROVED EQUAL, ARE APPROVED FOR LATERALS AND REPAIR WORK ONLY. 6" LATERALS SHALL BE CONSTRUCTED FROM THE SEWER MAIN TO EVERY LOT. ALL LATERALS SHALL BE PLACED PRIOR TO SURFACING OF STREETS, STAMP 'r ON CURB AT SEWER LATERAL LOCATIONS. SEWER MAIN SHALL BE AIR OR WATER TESTED MEETING DISTRICT ENGINEER'S APPROVAL. PRIOR TO ASPHALT CONCRETE PAVING, MANHOLE FRAMES AND COVERS SHALL BE LEFT 6' BELOW FINISH GRADE. AFTER STREET SURFACING IS COMPLETED, FRAMES AND COVERS SHALL BE RAISED TO GRADE PER STD. DWG. NO. S -105. SEWER MANHOLE FRAME AND COVER SHALL BE LHAMBRA FOUNDRY A -1270, OR APPROVED EQUAL. COVER TO BE STAMPED "SEWER." SEWER MAIN SHALL BE BALLED AFTER ALL MANHOLE FRAMES AND COVERS HAW BEEN RAISED TO GRADE. PVC PIPE MAY BE USED ONLY WITN PRIOR APPROVAL FROM THE DISTRMT ENGINEER, IF MINIMUM SEPARATION DISTANCE BETWEEN SEWER AND WATER MAIN IS NOT MET, SPECIAL CONSTRUCTION REQUIREMENTS ARE TO BE USED PER STD. DWG. NO. S- 110 -A OR S- 110-8. DEVELOPER IS RESPONSIBLE FOR REPLACING ANY EXISTING LATERALS NOT FOUND IN FIELD OR FOUND TO BE DEFECTIVE. ALL TRENCH EXCAVATION AND PIPE BEDDING SHALL BE DONE PER STD. DWG. NO. S -112. A CLEAN OUT WILL BE REQUIRED FOR EACH LOT ON PRIVATE PROPERTY BETWEEN RESIDENCE AND EDGE OF THE STREET RIGHT -OF -WAY. 15. INSTALL BLOW -OFF PER MCWD STANDARD DRAWING 1i9. 1 I E IMF NOTK TO COiVTAACTOF[ - - 16. WATER MAINS WILL BE TESTED AT 225 P.S.I. FOR FOUR HOURS. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES LINES AND IMPROVEMENT PLAN SHEET INDEX 3 THRU 8 STRUCTURES WHETHER SHOWN OR NOT SHOWN ON THIS PLAN, AND SHALL BE RESPONSIBLE 17. BACKFILL MATERIAL IN PIPE ZONE WILL HAVE A SAND EQUIVALENT OF 30 OR GREATER. FROM PROTECTING FROM DAMAGE. 18. THE BACKFILL ABOVE THE PIPE ZONE WILL BE COMPACTED PER MCWD STANDARD DRAWING THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN STREET LIGHT PULL BOX #18, AND BE IN COMPLIANCE WITH C.C.M. STANDARD DRAWING 813. ON THIS PLAN WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR T.C. TOP OF CURB KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CURB FACE T.E. CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILI- 19. CHIP 2" "W I N CURB FACE TO IDENTIFY WATER SERVICE LOCATION. TIES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS. 20. INSTALL THRUST OR GRAVITY BLOCKS PER MCWD DISTRICT STANDARD DRAWING #11 OR #12. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO T.G, TOP OF GRATE THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED 21. CONTRACTOR TO VERIFY DEPTH AND LOCATION OF ALL UTILITIES PRIOR TO TRENCHING, A SAFE PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCON- "OCCUPATIONAL E.P. EDGE OF PAVEMENT TRACTORS SHALL COMPLY WITH THE SAFETY AND HEALTH REGULATION" OF TOP OF WALL F.F. THE U.S. DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF 22. CONTRACTOR TO INSTALL TEMPORARY TAPS FOR TES71NO AND CHLORINAIM PRIOR TO INDUSTRIAL RELATIONS, "CONSTRUCTION SAFETY ORDERS ". THE CIVIL ENGINEER SHALL NOT BE FINISHED GRADE CONNECTING TO EXISTING MAINS. RESPONSIBLE FOR THE CONTRACTOR'S AND SUBCONTRACTORS COMPLIANCE WITH THE FEDERAL F.H. FIRE HYDRANT AND STATE REGULATIONS. 23. CONTRACTOR TO RETURN ALL MATERIAL REMOVED TO MCWD YARD, EXCEPT A.C.P., BROKEN CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION CONCRETE, AND NATIVE SOIL PRACTICES, CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPON- FINISHED SURFACE SIBILITY WATER METERS AND BOXES TO BE INSTALLED BY MCWD BUT PAID FOR BY 0IMERx INCLUDING SSAFETTY OF ALL PERSONS ANID PROPERTTYI,RAND THAT THHIIS REQUIREMENT SHALL FLOW ARROW G. M. APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONTRACTOR FURTHER 25. A REDUCED PRESSURE PRINCIPLE ASSEMBLY WILL BE REQUIRED ON ALL WATER METERED AGREES TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL AND OWNER HARMLESS FROM HIGH POINT SERVICES TO ANY CONDOMINIUM UNIT OVER TWO STORIES OR FIVE OR MORE UNITS ON ONE ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK INV. METERED SERVICE. CQt4TACT MAZER QUALITY AT (94Q) 574 -103t. ON THIS PROJECT. SEWER LINE LT THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD 26. IRRIGATION METERS WILL REQUIRE A REDUCED PRESSURE PRINCIPLE ASSEMBLY CONDITIONS IMMEDIATELY TO THE CIVIL ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, MANHOLE T -- AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. P.A. PLANTER AREA = -- 27. IN LANDSCAPED AREAS, NO TREES SHALL BE LOCATED IN MCWD EASEMENT OR WITHIN 7.5 OF ANY MCWD FACILITY. USES 28. A REDUCED PRESSURE PRINCIPLE ASSEMBLY WILL BE REQUIRED ON METERED WATER SERVICES CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE TO ALL INDUSTRIAL BUILDINGS, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ul I Y uF COSTA MESA Engineering Division Approval �S coTA MEA sANARY DBTFOT PACIFIC SOILS �. or Offste Improvements 10653 PROGRESS WAY � CYPRESS, CA. 90630 C pp t@ � tK 6nb PW _ 1 Phone (714) 220 -0070 ' \\ 3 yV CONTACT: DAVE HARWOOD ENLR awsirr PLJSiNm ctEI RL.,A pE `JD 0 REFERENCES BSICH MIIIR NQ /FB�N ELEVATIOWS&M MW OC! AMU DMWN BR DEBCR l"M WD R. W. OF THE W. DD OF THE NW. CUB RETURN OF HARBOR ELM AND F ns Of ooNSTRUICT1oN klEBA VERDE DRO 7 Ft K OF NORTH CUB FACE OF MEBA VERDE DR. i 0.7 R W. OF THE ME MCOMMADED WO CORNER OF A 72 R BY W R CONC. VAULT BUILT N AND LEWI L W/ RB]EWAU4 Nt R IL OF THE CA -O �� OF E MESA VERDE DR; 22D FL W. OF C/L OF HARBOR BLVDL AFFFAW D IM IE ACCT BY QTY 0OtNCL BABE OF BEARIO NOW417 CA. ADAM! AVE. BETWEEN M®A VERDE DR. AND HNNOR IM COUNTY OFRI Pq M + M ■ %il i I VICINITY MAP NOT TO SCALE DRAWING INDEX SHT. NO. DRAWING TITLE 1 TITLE SHEET 2 IMPROVEMENT PLAN SHEET INDEX 3 THRU 8 SEWER & WATER IMPROVEMENT PLANS (20' SCALE) A.C. ASPHALT CONCRETE P.P. POWER POLE A.B. AGGREGATE BASE R/W RIGHT OF WAY B. W. BACK OF WALK S. W. SIDEWALK C.B. CATCH BASIN S.L.P.B. STREET LIGHT PULL BOX C&C CURB R GUTTER T.C. TOP OF CURB C.F. CURB FACE T.E. TRASH ENCLOSURE C.Q. CLEAN OUT T.F. TOP OF FOOTING CENTERLINE T.G, TOP OF GRATE E.G. EDGE OF GUTTER T.P. TOP OF PAVEMENT E.P. EDGE OF PAVEMENT T. W. TOP OF WALL F.F. FINISHED FLOOR W.M. WATER METER F.G. FINISHED GRADE W.V. WATER VALVE F.H. FIRE HYDRANT 300 PROPOSED ELEVATION F.L. FLOW LINE EXISTING ELEVATION F.S, FINISHED SURFACE TREE GAL GRADE BREAK FLOW ARROW G. M. GAS METER SDI STORM DRAIN LINE H.P. HIGH POINT - W - WATER LINE INV. INVERT -S - SEWER LINE LT LIGHT --- -- GAS LINE M.H. MANHOLE T -- CABLE T.V. LINE P.A. PLANTER AREA = -- ELECTRICAL LINE P.L. PROPERTY LINE - -- TELEPHONE LINE SLURRY SEAL REaIJ�i 1. THE CONTRACTOR SHALL RESTORE THE ROADWAY SURFACE WITHIN THE WORK LIMITS BY SLURRY SEALING THE ENTIRE LANE(S) WHERE THE TRENCH IS LOCATED. A. FOR TRENCHES PERPENDICULAR TO TRAFFIC LANES: THE SLURRY SEAL SHALL EXTEND 50 FEET ON BOTH SIDES OF THE TRENCH AND WILL INCLUDE THE ENTIRE TRAVEL LANES. B. FOR TRENCHES PARALLEL TO TRAFFIC LANES AND FOR SMALL EXCAVATIONS: SLURRY SEAL THE ENTIRE WIDTH OF THE TRAFFIC LANE FOR THE FULL LENGTH OF THE TRENCH , BUT NOT LESS THAN 100' 2. RESTORATION OF THE ROADWAY SHALL BE CONTINUOUS AND NO JOINTS WILL BE ALLOWED. ALL ROADWAYS WITHIN THE WORK LIMITS WILL BE RESTORED IN ONE OPERATION. THE CONTRACTOR SHALL NOT PROCEED WITH THE SLURRY SEALING OPERATION UNTIL DIRECTION IS GIVEN BY THE CITY ENGINEER. .1 ANY EXISTING IMPROVEMENTS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED AS DIRECTED BY THE CITY ENGINEER. 4. SLURRY SEAL SHALL CONFORM TO SECTIONS 203 AND 302 -4 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. SLURRY SEAL SHALL BE QUICKSET EMULSION AGGREGATE SLURRY SEAL CATIONIC (QA -KH) TYPE It WITH 25 LATEX ADDITIVE. (OFF -SITE) MESA CONSOMATED WATER DISTFJCT - MC -160'3 JrR7O DATE APP. BY` DATE l f /ZAM Q -ESS/ IMPROVEN R. � 1 � HUITT-ZOLIARS HU WZCUM ITIM VW Mp6m^ TW ft CA 9V C7HA 2 7000 OF R.aL E1OD0 DAB[ � 3Wrs ILSI•�1 ° .78 SEWER & WATER Expiraton *�r�lE1 C31I -01 * T; 18882 - ADAMS AVENUE 8 MESA VERDE DRIVE OF CAI\ CITY OF COSTA MESA 1 61c'Er-ET 8 PLAN s NUM" ° 0 c JIM M- 0802-02 t s