S-01-1.1R z Z ' t n a P w I F_ 70 65 m 55 0 +00 Im I tr I I 30' 3'1 I20 I i 19=141 1+00 1+50 70 C:Y.7 P� , . 0 � m 55 A I I bS CONSTRUCTION NOTES CMSD STANDARD NOTES GENERAL NOTES 10-- TRENCH, REMOVAL & REPLACEMENT PER CITY OF COSTA MESA A. THE WATER SYSTEM IS TO BE INSTALLED BY THE DEVELOPER. ALL WATER SYSTEM VE OR ON A 8 1/2 X 11 PAPER (0NE SIDE ONLY) SHOWING LOCATION AND TIES OR LEVEL RUN. 2�STD. PLAN NO. 813. TO MINIMIZE THE APPARENT IMPACT WITHIN THE WORK AREA; SLURRY SEAL OVER AND 1. THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS OF THE COSTA MESA 1. ALL WORK AND MATERIALS WITHIN THE PUBLIC RIGHT -OF -WAY SHALL DESIGN REQUIREMENTS" AND "CONSTRUCTION MANUAL ", AS LAST REVISED. IMMEDIATELY ADJACENT TO THE TRENCH CUT. THIS WORK SHALL BE PERFORMED TO SANITARY DISTRICT. CONFORM TO THE CITY OF COSTA MESA STANDARDS, AND SHALL MEET BE USED TO PROTECT ADJOINING PROPERTIES DURING THE GRADING THE SATISFACTION OF THE SANITARY DISTRICT'S INSPECTOR. PROTECT ALL EXISTING 2. CONTRACTOR SHALL REQUEST INSPECTION FROM THE OFFICE OF THE DISTRICT WITH THE APPROVAL OF THE CITY ENGINEER. i PRIVATE AND PUBLIC IMPROVEMENTS IN PLACE.(ONSITE) ENGINEER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. TELEPHONE: (949) 2. ALL WORK SHALL BE PERFORMED AND ALL MATERIALS SHALL BE IN AGENCIES AND THE CONTRACTOR SHALL BE HELD ON THE JOB SITE 48 -HOURS PRIOR DRAINAGE PATTERNS. IF THE FOREGOING CANNOT BE COMPLETED WITH, 631 -1731. ACCORDANCE WITH THE STANDARD SPECIFICATION FOR PUBLIC WORKS A FULLY EXECUTED, NOTARIZED, AND RECORDED AGREEMENT BETWEEN REMOVE CLEANOUT AND JOIN EXISTING 8" VCP SEWER. 3. ANY WORK PERFORMED WITHOUT INSPECTION FROM THE DISTRICT SHALL BE CONSTRUCTION,(GREEN BOOK) CURRENT EDITION. OCONSTRUCT 48" SEWER MANHOLE PER COSTA MESA SANITARY DISTRICT STD. CONSIDERED UNACCEPTABLE. 3. CONTRACTOR SHALL FURNISH AN INSTALL ALL SIGNS, LIGHTS, CONTRACTOR NO. S -100. 4. CONTRACTOR SHALL OBTAIN CMSD SEWER PERMIT PRIOR TO COMMENCEMENT OF BARRICADES, FLASHING ARROW BOARD AND ANY OTHER TRAFFIC 69 WORK FROM THE DEPARTMENT OF STREETS AND SANITATION, CITY OF COSTA MESA, CONTROL OR WARNING DEVICES, INCLUDING FLAGMEN. AS MAY BE 50-- CONSTRUCT 8" VCP SEWER MAIN. 77 FAIR DRIVE. TELEPHONE: (949) 754 -5323. REQUIRED BY THE CITY ENGINEER. ALL ITEMS MENTIONED SHALL BE IN 6o--- CONSTRUCT 4" PVC LATERAL (SDR 35) 5. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS THAT MAY BE REQUIRED CONFORMANCE WITH THE CURRENT REQUIREMENTS AS SPECIFIED IN THE CONSTRUCT SEWER CLEAN OUT ONSITE &IMMEDIATELY ADJACENT TO PUBLIC RIGHT- BY THE LOCAL GOVERNING AGENCY. LATEST EDITION OF THE "CONSTRUCTION SAFETY ORDERS ", AND THE DISTRICT. OF -WAY PER COSTA MESA SANITARY DISTRICT STD. N0. 5 -107 6. CONTRACTOR TO HAVE A COPY OF APPROVED SEWER PLAN AND CMSD STANDARD W.A.T.C.H. FAILURE TO DO SO WILL BE CITED UNDER APPLICABLE PLANS AND SPECIFICATIONS ON JOB SITE AT ALL TIMES. SECTION OF THE C.V.C. AND CORRECTIVE COST TO THE CITY WILL BE 8o--- SLURRY BACKFILL TRENCH WITH 3 SACK SAND SLURRY. PROTECT EXISTING WALL 7. CLAY PIPE JOINTS SHALL BE TYPE "G" MECHANICAL COMPRESSION JOINTS FOR CHARGED. AND FOOTING IN PLACE, SEE DETAIL "A" THIS SHEET.(ONSITE) MAIN LINE SEWER. TYPE "D" JOINTS, BAND -SEAL OF APPROVED EQUAL, ARE 4. THE CONTRACTOR SHALL OBTAIN ENGINEERING DIVISION PERMITS 99 -JOIN EXISTING LATERAL. APPROVED FOR LATERALS AND REPAIR WORK ONLY. PRIOR TO START OF ANY ON -SITE CONSTRUCTION AND /OR GRADING AND 10 CONSTRUCT CLEANOUT B. 8. 6" LATERALS SHALL BE CONSTRUCTED FROM THE SEWER MAIN TO EVERY LOT. REQUEST INSPECTION FROM CITY ENGINEERING DIVISION 48 HOURS IN 9. ALL LATERALS SHALL BE PLACED PRIOR TO SURFACING OF STREETS. ADVANCE OF PERFORMING ANY WORK. TELEPHONE (714) 754 -5323. THE 11 SAW CUT, REMOVE AND REPLACE EXISTING CURB AND GUTTER FOR A MINIMUM 10. STAMP "S" ON CURB AT SEWER LATERAL LOCATIONS. CONTRACTOR SHALL MAINTAIN A COPY OF THE PERMITS AND SIGNED LENGTH OF 8 FT OR 1 FT GREATER THAN TRENCH WIDTH , SEE DETAIL THIS 11. SEWER MAIN SHALL BE AIR OR WATER TESTED MEETING DISTRICT ENGINEER'S PLANS ON THE JOB SITE. SHEET. CURB & GUTTER REPLACEMENT PER CITY OF COSTA MESA STD. 312 (C -6). APPROVAL. S. PERMITS WILL BE REQUIRED FROM THE IRVINE RANCH WATER 12 LOCATE EXISTING SEWER LATERAL AT R/W AND PLUG. ALL REMAINING PORTIONS 12. PRIOR TO ASPHALT CONCRETE PAVING, MANHOLE FRAMES AND COVERS SHALL THE COSTA MESA SANITATION DISTRICT FOR CONSTRUCTION OF WATER INSIDE PUBLIC R/W SHALL BE PROTECTED IN PLACE AND SERVICEABILITY SHALL BE LEFT 6" BELOW FINISH GRADE. AFTER STREET SURFACING IS COMPLETED, FRAMES AND SEWER IMPROVEMENTS . BE VERIFIED PRIOR TO AND COVERS SHALL BE RAISED TO GRADE PER STD. DWQ. N0. 5 -105. PLUG 13. SEWER MANHOLE FRAME AND COVER SHALL BE ALHAMBRA FOUNDRY A -1270, OR 6. ESTIMATED QUANTITY OF CUT = 0 YDS. ESTIMATED QUANTITY OF 13 EMAINILLING. BOTH ENDS OF REMAINING PRIVATE LATERAL AND ABANDON IN PLACE. APPROVED EQUAL COVER TO BE STAMPED 'SEWER'. FILL = 0 YDS. 14 TAP EXISTING 8" AC WATER MAIN &PLACE SERVICE LINE PER IRVINE RANCH 14. SEWER MAIN SHALL BE BALLED AFTER ALL MANHOLE FRAMES AND COVERS HAVE 7. THE CONTRACTOR SHALL PAY FOR THE INITIAL SOIL AND MATERIALS DISTRICT STD. DRAWING W -1, METER TO BE 5/8 X 3/4 ". T BEEN RAISED TO GRADE. TESTS AND SUBSEQUENT SOIL AND MATERIALS TESTS DEEMED ISWATER - PLACE 1" REDUCED PRESSURE BACKFLOW ASSEMBLY PER IRVINE RANCH WATER 15. PVC PIPE MAY BE USED ONLY WITH PRIOR APPROVAL FROM THE DISTRICT NECESSARY, DUE TO THE FAILURE OF THE INITIAL TESTS, AS DISTRICT STD. DRAWING W -20. ENGINEER. DETERMINED BY THE CITY ENGINEER. 16. IF MINIMUM SEPARATION DISTANCE BETWEEN SEWER AND WATER MAIN IS NOT 8. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING 16 PARTIAL DRIVEWAY APPROACH REMOVAL PER COSTA MESA STD 811. MET, SPECIAL CONSTRUCTION REQUIREMENTS ARE TO BE USED PER STD. DWG. N0. UTILITIES IN PLACE. RECONSTRUCTION PER STD 513 (6-PCC, 6 "CMB). S -110 -A OR S- 110 -B. 9. ALL CONSTRUCTION STAKING SHALL BE DONE BY A LICENSED SURVEYOR A�CONTRACTOR TO EXPOSE EXISTING LATERAL AND VERIFY ITS 17. DEVELOPER IS RESPONSIBLE FOR REPLACING ANY EXISTING LATERALS NOT FOUND OR ENGINEER AND CERTIFIED IN WRITING AS TO LINE AND GRADE PER ELEVATION. IF THE ELEVATION IS FOUND TO BE HIGHER THAN THE IN FIELD OR FOUND TO BE DEFECTIVE. APPROVED PLAN AD SUBMITTED TO THE CITY ENGINEER. PROPOSED LATERAL, THE CONTRACTOR SHALL RAISE THE PROPOSED 18. ALL TRENCH EXCAVATION AND PIPE BEDDING SHALL BE DONE PER STD. DWQ. 10. NO WORK SHALL BE DONE ON ADJACENT PROPERTIES OF ADJACENT LATERAL'S ELEVATION THERE BY LESSENING THE IMPACT ON THE NO. S -112. OWNERS IMPROVEMENTS WITHOUT OBTAINING WRITTEN PERMISSION FROM THE OWNERS OF THE ADJACENT PROPERTIES, AND SUBMITTING A EXISTING WALL FOOTING. SEE DETAIL "A" THIS SHEET. THE MINIMUM COPY T THE CITY ENGINEERING DIVISION. DEPTH OF COVER OVER THE LATERAL SHALL HAVE A MIN. COVER 11. WORK, ONCE BEGUN, SHALL BE PROSECUTED TO COMPLETION OF 2.5'. THE CONTRACTOR IS TO CONSULT WITH THE ENGINEER ON THE FINA WITHOUT DELAY SO AS TO PROVIDE MINIMUM INCONVENIENCE TO PROFILE SCALES HOIZ: 1"=20' VERT: 1"=2' L DETERMINATION OF GRADES. CONTRACTOR TO ALLOW 48 PROPERTY OWNERS AND THE TRAVELING PUBLIC. HOURS FOR ENGINEER'S REVIEW. 12. ALL STREET STATIONING REFERS TO THE CENTER LINE OF THE g CONTRACTOR TO EXPOSE EXISTING SEWER AND VERIFY ITS ELEVATION STANDARD WATER NOTES 13.. STREET ALL UNDERGROUND AWORKR SHALL BE COMPLETE TO ANY PRIOR TO ANY CONSTRUCTION. NOTIFY ENGINEER IF ANY SURFACE WORK IN THE PUBLIC RIGHT -OF -WAY. ADJUSTMENTS ARE REQUIRED, ALLOW 48 HOURS FOR ENGINEERS THE FOLLOWING STANDARD WATER NOTES SHALL BE INCLUDED ON ALL IMPROVEMENT 14. ANY LOT CORNER OR OCEMA BM, MONUMENT OR TIE DESTROYED OR REVIEW. DISPLACED SHALL BE RESTORED TO ITS ORIGINAL POSITION BY A PLANS FOR THE INSTALLATION OF DOMESTIC WATER SYSTEMS: LICENSED ENGINEER OR LAND SUR Y _ A � Tr " - A. THE WATER SYSTEM IS TO BE INSTALLED BY THE DEVELOPER. ALL WATER SYSTEM VE OR ON A 8 1/2 X 11 PAPER (0NE SIDE ONLY) SHOWING LOCATION AND TIES OR LEVEL RUN. x WORK SHALL CONFORM TO THE DISTRICTS "PROCEDURAL GUIDELINES AND GENERAL 15. ALL EXISTING DRAINAGE COURSES ON THE PROJECT MUST CONTINUE / DESIGN REQUIREMENTS" AND "CONSTRUCTION MANUAL ", AS LAST REVISED. TO FUNCTION, ESPECIALLY DURING STORM CONDITIONS, AND APPROVED PROTECTIVE MEASURES AND TEMPORARY DRAINAGE PROVISIONS MUST j B. THE DISTRICT ENGINEERING OFFICE SHALL BE CALLED FOR INSPECTION FOUR (4) BE USED TO PROTECT ADJOINING PROPERTIES DURING THE GRADING TRACT 3433 WORKING DAYS BEFORE START OF WORK AT (714) 453 -5300 OR (714) 453 -5615. PROJECT. IN ALL CASES, THE CONTRACTOR AND /OR DEVELOPER SHALL i C. APRE- CONSTRUCTION CONFERENCE OF REPRESENTATIVES FROM AFFECTED BE HELD LIABLE FOR ANY DAMAGE DUE TO OBSTRUCTION OF NATURAL f AGENCIES AND THE CONTRACTOR SHALL BE HELD ON THE JOB SITE 48 -HOURS PRIOR DRAINAGE PATTERNS. IF THE FOREGOING CANNOT BE COMPLETED WITH, -J c , A FULLY EXECUTED, NOTARIZED, AND RECORDED AGREEMENT BETWEEN WALL / J x TO START OF WORK. EFFECTED PARTIES WILL BE EFFECTED. pl D. THE WATER SYSTEM IS TO BE STAKED BY THE DEVELOPER'S ENGINEER AT A 16. ALL HAUL ROUTES MUST BE APPROVED BY THE CITY ENGINEER. CONTRACTOR MINIMUM 50 -FOOT STATIONING IF THERE ARE NO EXISTING CURBS, 17. THE PROJECT SITE SHALL BE MAINTAINED IN A "WET -DOWN" 69 < < E. ANY WATER SERVICE FUND TO BE WITHIN A DRIVEWAY OR SIDEWALK SHALL BE CONDITION TO THE DEGREE NECESSARY TO PREVENT EXCESSIVE DUST. / AA MINIMUM OF 72 HRSPRIOR� 0 THE WRITING THE SITE QUA COMMENCE ENT OF ANY WORN A B. REMOVED COMPLETELY AND RE- INSTALLED AT THE PROPER LOCATION AT NO COST TO PERIODICALLY, SPILLAGE AND DUST SHALL BE REMOVED FROM THE THE DISTRICT. PUBLIC RIGHT -OF WAY BY SWEEPING OR SPRINKLING HOWEVER ELEC SCE PAULARINO S LLJ w 6� RISER 36k5� SOP Q I Z x �� 4) IRR. VALVE I 6 > W I GATE j 5E w GATE POWER POLE ,Q;} I / EP GPC1O a / (TYP.) 665Q'y�pVQ�PG� 8 I ) G 06 5 pv� a.` I I SSG gJQJTC 66.5 I x G / 4' SEw£R 0 pR� lr �i 0 � \ ��i� ��, �A BRA 11. � � ` � 10' I LT R/W 10 5g 53 2�� F\ ��EXIST. EDISON TW - I 6a's � g 35 +43 CL 8" SEWER N r00 a S ti I MONTE VISTA AV •- I I .; '.' I \�,, MONACO `TE-RRACE l�s� \ 1 s534�FC 1 5 ok34 0 +00 CL MONACO TERRACE y _` RJ �rmo x' 06 N m 66.5'I OFFK. I 4 ,6 4 F( 8804 i 11 " 11 S r L ------------- - r r- ( 1r 1 1 Q I 1 ��2 1�.,_ - - - - ---r - -� - 6 ly EXIST. EDISON - E- - 2 0X -�1 4 LL1 LOT 22� Z I o TRAFFIC CONTROL NOTE I 1 2 ���" II I1 ALL TRAFFIC CONTROL SHALL BE PER THE w TRACT 3433 B W I ro�O �' LATEST ADDITION OF THE "WORK AREA I F �� TRAFFIC CONTROL HANDBOOK" (W.A.T.C.H.). I I \ 1� u I �PLOURDES LN. I I I II EX. BLOCK WALL & FOOTING IRVINE RANCH WATER DISTRICT PROTECT IN PLACE COSTA MESA SANITARY DISTRICT S APPROVAL OF };� Wq FACILITIES 1.33' APPROVED FOR WORK WITHIN MONACO TERRACE RIGHT -OF -WAY AND LOURDES LANE EASEMENT. 1/ 90t7 _i �yy APR VED BY DATE COMPACT TO 90% r - -I_� t� "SEX. PCC JI Ib LI SUPERNSED BY DATE PLACE 3 SACK SLURP 45' FOOTING D TRICT ENGINEER DATE BACKFILL REVIEWED BY DATE e CITY OF COSTA MESA BENCH MARK: SAND WITH MIN. OF APPROVED FOR WORK WITHIN MONACO TERRACE SAND EQU. OF 25 OR RIGHT -OF -WAY, ___ __.._ _..__..._.... BENCH MARK: TBM AT EASTERLY BCR OF NORTH EASTERLY #4 ROCK. �y A CURB RETURN OF MONACO TERRACE AND DETAIL A" �� �\�`'! • O V MONTE VISTA AVE. PER STREET PLAN NO.76 -2.1 TC BCR ELEV.= 66.83 NO SCALE 'Im DATE (FOR SEWER CONSTRUCTION ONLY) J,BSTATION F. ALL MAIN LINE VALVES SHALL BE MAINTAINED SO AS TO BE ACCESSIBLE DURING TRACT DEVELOPMENT, AND ALL VALVE STEM TOPS HAVING OVER 48- INCHES OF COVER / Li WILL REQUIRE AN EXTENSION AS PER DRAWING W -8. \ x G. IN RESIDENTIAL STREETS, THE TOP OF THE PIPE, 10- INCHES AND SMALLER, SHALL BE A MINIMUM OF 42- INCHES BELOW THE FINISHED STREET SURFACE AND 48- INCHES % BELOW FINISHED STREET SURFACE ON ALL PRIMARY AND SECONDARY STREETS. H. ALL FIRE HYDRANTS SHALL BE SET WITH THE BOTTOM FLANGE 4- INCHES ABOVE 4" GRAVEL THE CONCRETE PAD OR SIDEWALK WITHOUT THE USE OF SPOOLS AND SHALL BE WATERING THAT RESULTS IN MUD IN PUBLIC STREETS IS NOT PERMITTED AS A SUBSTITUTE FOR OTHER CLEANING METHODS. 18. ALL UTILITY TRENCH BACKFILL, MATERIAL, AND COMPACTION SHALL CONFORM TO CCM STANDARD NO. 813. BORE UNDER EXISTING IMPROVEMENTS - TUNNELING IS NOT ALLOWED. NO OPEN EXCAVATIONS WILL BE ALLOWED OVER NIGHT - BACKFILL OR PLATE. 19. ALL PCC AND AC TO BE JOINED SHALL BE SAWCUT IN A CLEAN, STRAIGHT LINE AS APPROVED BY THE CITY ENGINEER. 20. "AS BUILT" DRAWINGS SHALL BE SUBMITTED V THE CITY LOCATED A MINIMUM OF 3 FEET FROM THE ECR OR BCR AT INTERSECTION. ENGINEERING DIVISION UPON COMPLETION OF IMPROVEMENTS AS / SHOWN ON THE APPROVED PLANS. / I. ALL WATER MAINS 6- INCHES THROUGH 12- INCHES SHALL BE CLASS 150, AWWA X C -900 PVC, UNLESS OTHERWISE NOTED. (65.09) �6SS J. NO TAPS OR OTHER CONNECTIONS SHALL BE MADE TO EXISTING DISTRICT WATER 5 61 J �� GS T� �) MAINS PRIOR TO CONDUCTING AN APPROVED PRESSURE TEST ON THE NEW WATER NOTICE TO CONTRACTOR 65- cS ?2J J r DISTRIBUTION SYSTEM. TAPPING SLEEVES SHALL BE PRESSURE TESTED IN AN APPROVED MANNER IN THE FIELD, IN THE PRESENCE OF THE DISTRICT INSPECTOR, PRIOR TO TAPPING THE MAIN LINE. TAPPING OF THE MAIN LINE SHALL NOT PROCEED THE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH 65.22 I i UNLESS A DISTRICT INSPECTOR IS PRESENT. GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE 522i 52 / REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE K. WHERE METERS AND METER BOXES ARE LOCATED WITHIN SLOPES, THE ANGLE METER STOPS SHALL BE SO LOCATED THAT THE METERS AND BOXES WILL BE PARALLEL AND JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE 0 _ PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT GS GS Y j I;. RET. WALL FLUSH, RESPECTIVELY, WITH THE FINISHED SURFACE. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT 65.53 L. NO METER IS TO BE PLACED WITHIN ANY SIDEWALK OR DRIVEWAY AREA. BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION w TW / ) M. CURBS SHALL BE INSCRIBED WITH A "W" INDICATING LOCATIONS OF ALL DOMESTIC CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONS HARMLESS FROM ANY AND ALL LIABILITY , REAL TW r WATER SERVICES. 65.10 N. INDIVIDUAL PRESSURE REGULATORS ARE REQUIRED BY THE UNIFORM PLUMBING OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE TW CODE IF AVERAGE STATIC PRESSURE IN THE MAIN IS 80 PSI OR MORE. NEGLIGENCE OF DESIGN PROFESSIONAL. ALL EXISTING TOPOGRAPHY 0. CURBS SHALL BE INSCRIBED WITH TIE DOWNS FOR ALL VALVE LOCATIONS. AND PROPOSED GRADES SHOULD BE FIELD VERIFIED BY THE DROP INLET CONTRACTOR PRIOR TO COMMENCING CONSTRUCTION. 6 P. THE CONTRACTOR SHALL EXPOSE ALL JOIN POINTS TO THE EXISTING DOMESTIC - WATER SYSTEM FOR VERIFICATION OF HORIZONTAL AND VERTICAL LOCATION BEFORE '- = CONSTRUCTION. UNDERGROUND STRUCTURES 5 SER RET. WALL Q. FINAL INSPECTION FOR WATERLINES MUST INCLUDE WATER SAMPLES THAT WILL BE MONACO s� (62.51)TC TESTED FOR CONDUCTIVITY, TURBIDITY AND ODOR. THE TURBIDITY MUST BE LESS THAN SEAR RWM °�`� s 6a(62.03)FL (61.56)TC 2.5 NTU AND THE ODOR MUST BE LESS THAT 1.0 TON, NOT TO INCLUDE CHLORINE THE CONTRACTOR BY ACCEPTING THESE PLANS OR 6 CU} & GUtER _ (sl.os)FL ODOR, TO BE ACCEPTABLE. PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED + R. THE CONTRACTOR WORKING ON IRWD WATERLINES MUST HAVE A C -34 LICENSE OR HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF (62.99)TQ ' EX.i GAS LINE A CLASS A GENERAL CONTRACTORS LICENSE UNDERGROUND UTILITIES OR STRUCTURES SHOWN OR NOT SHOWN AND (62.48 L / G ` EX. 8" AC WATER S. CONTRACTOR SHALL OBTAIN AND SHOW PROOF OF A DEWATERING PERMIT FROM THE NOT REPORTED TO THE UNDERSIGNED; NOT INDICATED ON THE PUBLIC RECORDS EXAMINED; LOCATED AT VARIANCE WITH THAT REPORTED OR �`� - - - - - - - - - - - - - - - - - - - - STATE OF CALIFORNIA, REGIONAL WATER QUALITY CONTROL BOARD PRIOR TO THE START - - - - - OF CONSTRUCTION, SHOWN ON RECORDS SUPPLIED. THE CONSTRUCTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR �--- - STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND - - / AND NOT SHOWN AT THE SITE. IT SHALL BE THE CONTRACTOR'S _ RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES - -- - - - - - -- IMMEDIATELY UPON THEIR DISCOVERY. A UTILITY SEARCH BY THE L) CONTRACTOR SHOULD BE CONDUCTED. UNDERGROUND SERVICE ALERT �O 1 SHALL BE CONTACTED AT LEAST TWO WORKING DAYS PRIOR TO ANY DIGGING. LOT 23 .� N �. EXISTING ASPHALT _ 3 /s" 14 TRACT 3433 GP� - 1 S _ -J c , NOTE TO CONTRACTOR - < < THE CONTRACTOR NOTIFY IMPACTED K AA MINIMUM OF 72 HRSPRIOR� 0 THE WRITING THE SITE QUA COMMENCE ENT OF ANY WORN A B. ■E LL BE POSTED IN A CONSPICUOUS MANNER STATING THE DATE, TIME, DURATIONS TYPE OF WORK THAT WILL BE PERFORMED AND THE NAME AND PHONE COMPACT 90% 1 NOTICE TO CONTRACTOR OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR // �/ COORDINATION WITH ALL ADJACENT IMPACTED RESIDENCES. PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERMIT IS NOTE: SAWCUT, REMOVE AND REPLACE EXISTING AC PAVEMENT VAUD UNLESS THE FOLLOWING IS PERFORMED: IN KIND PLUS 1" EXTRA AC, COMPACT SUB -GRADE TO 90 %). OWNER' CURB TO BE SAWCUT AND REMOVED OR REMOVED BACK TO 1. UNDERG QUN SERMC ALERT HA B N CONTACTED AND c CLOSEST COLD JOINT. HAS PROVIDED INQUIRY I.D.# -91 Ali SOUTHERN CALIFORNIA EDISON 2. THE UNDERSIGNED AGREES TO CONTACT AND OBTAIN AN r INQUIRY I.D. ,f FROM UNDERGROUND SERVICE ALERT LOS ANGELES 1Y CURB & GUTTER REMOVAL AND REPLACEMENT (1- 800- 422 -4133 AT AST TWO (2) WORKING DAYS NO SCALE PRIOR TO COMMENC ME OF EXCAVATION DATE DESCRIPTION CIVIL ENGINEER CJ �UU Jeff Oviedo & Asmdi $eS, hx DATE CONSULTING ENGINEERS QROFE 3151 Airway Ave. �o �� G Suite F- 2034<�`� Costa Mesa, California 92626 W Phone (714) 662 -0740 Fax (714) 662 -0125 of SIGN 6'-,U DATE i/ -/0- :.C&0 EWER & WATER SERVICE RELOCATION FOR PROJECT NO. SCE3 DATE FIRST PLOTTED: SCE PAULARINO SUBSTATION 10/23,2000 MONACO TERRACE & MONTE VISTA AVE. SHEET OF 1 1 SHEETS 3 7 S J